Cable layout and connections
67
851-164574 / C
2
Terminate the cable shielding.
→
Cable shielding is shown in figure 23.
Cable
main
screen
(CD3117)
Figure 23 Termination of
cable shielding
3
Terminate the seven cable pairs onto terminal block E201 in
the Transceiver Unit.
- For the insulation of the shielding of each of the cable
pairs, use part of the supplied cable sleeve.
→
Refer to the cable connection drawing on page 180 for
termination details for E201.
4
Run the cable from the Transceiver Unit to the Motor
Control Unit mounted on the gantry.
5
Use the cable gland on the right-hand side in the Motor
Control Unit, and terminate the cable shielding in the cable
gland.
→
The cable shielding is described in figure 23 on page 67.
→
The interior of the Motor Control Unit is shown in figure
24.
6
Create a small cable slack inside the Motor Control Unit as
indicated in the figure.
7
Make the E301 connections in the Motor Control Unit
according to the cable connection drawing.
- Note that the shielding of each cable pair shall not be
connected in the Motor Control Unit.
→
Refer to the cable connection drawing on page 180.
Содержание SP60 - REV D
Страница 2: ......
Страница 14: ...Simrad SP60 X 851 164574 C Notes...
Страница 61: ...Transceiver unit 45 851 164574 C Figure 13 Mounting the Transceiver Unit CD3110A...
Страница 203: ...Drawing file 187 851 164574 C 13 3 Installation drawings The SP60 installation drawings are provided on the next pages...
Страница 213: ...Installation remarks 197 851 164574 C Party Date Signature Party Date Signature Party Date Signature...
Страница 214: ...Notes...
Страница 215: ...Notes...
Страница 217: ......