Start-up procedures
115
851-164574 / C
Actions on the bridge
Note
This procedure must be performed simultanously with the next
procedure;
Actions in the sonar room
.
The instructions marked
Sonar room
are performed in the sonar
room.
1
Start up the sonar.
2
Check that the depth is sufficient for lowering of the
transducer.
3
Lower the transducer to middle position by giving a short
press on the
Middle
button.
4
Set the
TX Power
in the
Horizontal
menu to
Low
, and
check that echoes appear on the display.
5
Sonar room:
Check that the voltmeter on the HV Power unit
shows approximately 25 V.
6
Sonar room:
Check that the
TX Enable
LED (TXEN) on
the TIB board starts flashing.
→
For location of the TXEN LED, refer to figure 38 on page
114.
7
Set the
TX Power
in the main menu to
Medium
, and check
that the echoes become stronger.
8
Sonar room:
Check that the voltmeter on the HV Power unit
shows approximately 50 V.
9
Set the
TX Power
in the
Horizontal
menu to
Full
, and check
that the echoes become even stronger.
10
Sonar room:
Check that the voltmeter on the HV Power unit
shows approximately 100 V.
If the Hull Unit is installed differently from the recommended
orientation, the echo picture on the display must be aligned to show
the echoes in correct position.
→
Refer to
Alignment of the sonar picture
on page 118.
Содержание SP60 - REV D
Страница 2: ......
Страница 14: ...Simrad SP60 X 851 164574 C Notes...
Страница 61: ...Transceiver unit 45 851 164574 C Figure 13 Mounting the Transceiver Unit CD3110A...
Страница 203: ...Drawing file 187 851 164574 C 13 3 Installation drawings The SP60 installation drawings are provided on the next pages...
Страница 213: ...Installation remarks 197 851 164574 C Party Date Signature Party Date Signature Party Date Signature...
Страница 214: ...Notes...
Страница 215: ...Notes...
Страница 217: ......