Start-up procedures
117
851-164574 / C
Actions in the sonar room
Note
This procedure must be performed simultanously with the previous
procedure;
Actions on the bridge
.
The instructions marked
Bridge
are performed on the bridge.
1
Bridge:
Start up the sonar.
2
Bridge:
Check that the depth is sufficient for lower the
transducer
3
Bridge:
Lower the transducer to middle position by giving
a short press on the middle button.
4
Bridge:
Set the
TX Power
in the
Horizontal
menu to
Low
and check that echoes appear on the display.
5
Check that the voltmeter on the HV Power unit shows
approximately 25 V.
6
Check that the
TX Enable
LED (TXEN) on the TIB board
starts flashing.
→
For location of the TXEN LED, refer to figure 38 on page
114.
7
Bridge:
Set the
TX Power
in the
Horizontal
menu to
Medium
, and check that the echoes become stronger.
8
Check that the voltmeter on the HV Power unit shows
approximately 50 V.
9
Bridge:
Set the
TX Power
in the
Horizontal
menu to
Full
,
and check that the echoes become even stronger.
10
Check that the voltmeter on the HV Power unit shows
approximately 100 V.
Содержание SP60 - REV D
Страница 2: ......
Страница 14: ...Simrad SP60 X 851 164574 C Notes...
Страница 61: ...Transceiver unit 45 851 164574 C Figure 13 Mounting the Transceiver Unit CD3110A...
Страница 203: ...Drawing file 187 851 164574 C 13 3 Installation drawings The SP60 installation drawings are provided on the next pages...
Страница 213: ...Installation remarks 197 851 164574 C Party Date Signature Party Date Signature Party Date Signature...
Страница 214: ...Notes...
Страница 215: ...Notes...
Страница 217: ......