Simrad SP60
150
851-164574 / C
12 TECHNICAL SPECIFICATIONS
12.1 Power specifications
Sonar Processor Unit MC70
•
Voltage:
-
Nominal:
115 / 230 Vac, single phase (selectable)
-
Deviation:
15 % of nominal voltage
-
Transient:
20 % of nominal voltage, recover time 3 s
•
Power consumption:
150 VA
•
Frequency:
47 to 63 Hz
Transceiver Unit
•
Voltage:
-
Nominal:
115 / 230 Vac, single phase (automatic)
-
Deviation:
15 % of nominal voltage
-
Transient:
20 % of nominal voltage, recover time 3 s
•
Power consumption:
600 VA
•
Frequency:
47 to 63 Hz
Hull Unit
•
Voltage:
-
Nominal:
230 / 380 / 440 Vac, 3-phase (selectable)
-
Deviation, 230 Vac:
15 % of nominal voltage
-
Deviation, 380 / 440 Vac:
340 to 485 Vac
-
Transient:
20 % of nominal voltage, recover time 3 s
•
Power consumption:
3000 VA max
•
Frequency:
47 to 63 Hz
Sonar Interface Unit
Not applicable.
Display Unit
Refer to the documentation for the applicable unit.
12.2 Weights and dimensions
Operating Panel
•
Weight:
Approximately 4 kg
•
Dimensions (WDH):
385 x 165 x 58 mm
→
Refer to drawing 834-204688 on page 188.
Содержание SP60 - REV D
Страница 2: ......
Страница 14: ...Simrad SP60 X 851 164574 C Notes...
Страница 61: ...Transceiver unit 45 851 164574 C Figure 13 Mounting the Transceiver Unit CD3110A...
Страница 203: ...Drawing file 187 851 164574 C 13 3 Installation drawings The SP60 installation drawings are provided on the next pages...
Страница 213: ...Installation remarks 197 851 164574 C Party Date Signature Party Date Signature Party Date Signature...
Страница 214: ...Notes...
Страница 215: ...Notes...
Страница 217: ......