![Simrad SC90 Скачать руководство пользователя страница 296](http://html.mh-extra.com/html/simrad/sc90/sc90_installation-manual_1278958296.webp)
294
419050/B
• The
Lower Limit Switch
(S305) must be deactivated (with the transducer in upper
position or on its way down).
• The
Hand Crank Switch
(S203) must be closed with the hand crank in its storage
position.
WARNING
High voltages are used. This equipment must only be serviced by qualified
personnel familiar with high-voltage equipment and the potential hazards
involved. Failure to observe this precaution could result in bodily injury.
Procedure
1
Locate the
Motor Protecting Switch
(S301). Press the operating handle down to
position
OFF
.
2
Make sure that the LED indicator
L2
on the front of the 24 VDC power supply is lit.
3
Locate
Hoist/Lower Switch
(S302). Set the switch to position
HOIST
.
4
Make sure that
Hoisting Contactor
(K301) is not activated.
If
Hoisting Contactor
(K301) is activated:
a
Locate
Upper Limit Switch
(S304) on the hull unit (inside the gantry, at the top).
b
Press
Upper Limit Switch
(S304) up to activate it.
c
Make sure that the
Hoisting Contactor
(K301) is deactivated.
5
Locate
Hoist/Lower Switch
(S302). Set the switch to position
LOWER
.
6
Verify that
Lowering Contactor
(K302) is activated.
7
Locate
Lower Limit Switch
(S305) on the hull unit (inside the gantry, at the bottom).
Press
Lower Limit Switch
(S305) down to activate it.
8
Verify that
Lowering Contactor
(K302) is activated when you activate
Lower Limit
Switch
(S305).
9
Locate the hand crank inside the Motor Control Unit. Remove the hand crank
from its storage position.
10
Verify that
Lowering Contactor
(K302) is deactivated.
Do not place the hand crank back into its storage position.
11
Locate
Hoist/Lower Switch
(S302). Set the switch to position
STOP
.
Result
Requirements
Results
The
Hoisting Contactor
(K301) is functional.
The
Lowering Contactor
(K302) is functional.
Date and signature:
Simrad SC90 Installation Manual
Содержание SC90
Страница 2: ......
Страница 16: ...14 419050 B Simrad SC90 ...
Страница 219: ...419050 B 217 Øverland UPC 3005 Dimensions Cable layout and interconnections ...
Страница 223: ...419050 B 221 Øverland UPC 5000P Dimensions Cable layout and interconnections ...
Страница 364: ...362 419050 B Requirements Results A noise speed curve is created Date and signature Simrad SC90 Installation Manual ...
Страница 438: ...436 419050 B 427177 Transducer dock dimensions page 494 Simrad SC90 Installation Manual ...
Страница 441: ...419050 B 439 Drawing file ...
Страница 442: ...440 419050 B Simrad SC90 Installation Manual ...
Страница 445: ...419050 B 443 Drawing file ...
Страница 451: ...419050 B 449 413125 Hull Unit dimensions SC90 Download the source drawing from https www simrad com sc90 Drawing file ...
Страница 452: ...450 419050 B Simrad SC90 Installation Manual ...
Страница 455: ...419050 B 453 Drawing file ...
Страница 458: ...456 419050 B Simrad SC90 Installation Manual ...
Страница 463: ...419050 B 461 Drawing file ...
Страница 468: ...466 419050 B Simrad SC90 Installation Manual ...
Страница 469: ...419050 B 467 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Страница 471: ...419050 B 469 Drawing file ...
Страница 472: ...470 419050 B Related topics Installing the optional gate valve DN500 page 103 Simrad SC90 Installation Manual ...
Страница 473: ...419050 B 471 214043 Gate valve installation DN350 Drawing file ...
Страница 474: ...472 419050 B Related topics Installing the optional gate valve DN350 page 84 Simrad SC90 Installation Manual ...
Страница 475: ...419050 B 473 422915 Gate valve installation DN350 Drawing file ...
Страница 476: ...474 419050 B Related topics Installing the optional gate valve DN350 page 84 Simrad SC90 Installation Manual ...
Страница 477: ...419050 B 475 083045 Gate valve installation DN500 Drawing file ...
Страница 478: ...476 419050 B Related topics Installing the optional gate valve DN500 page 103 Simrad SC90 Installation Manual ...
Страница 479: ...419050 B 477 33414 Gate valve dimensions DN350 Drawing file ...
Страница 480: ...478 419050 B Simrad SC90 Installation Manual ...
Страница 481: ...419050 B 479 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Страница 482: ...480 419050 B 33473 Gate valve dimensions DN350 Simrad SC90 Installation Manual ...
Страница 483: ...419050 B 481 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Страница 484: ...482 419050 B 33498 Gate valve dimensions DN500 Simrad SC90 Installation Manual ...
Страница 485: ...419050 B 483 Drawing file ...
Страница 486: ...484 419050 B Related topics Installing the optional gate valve DN500 page 103 Simrad SC90 Installation Manual ...
Страница 487: ...419050 B 485 37357 Gate valve dimensions DN500 Drawing file ...
Страница 488: ...486 419050 B Simrad SC90 Installation Manual ...
Страница 489: ...419050 B 487 Related topics Installing the optional gate valve DN500 page 103 Drawing file ...
Страница 491: ...419050 B 489 Drawing file ...
Страница 493: ...419050 B 491 430192 Transducer dock dimensions Download the source drawing from https www simrad com sc90 Drawing file ...
Страница 494: ...492 419050 B Simrad SC90 Installation Manual ...
Страница 495: ...419050 B 493 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Страница 497: ...419050 B 495 Drawing file ...
Страница 498: ...496 419050 B Related topics Installing the optional gate valve DN500 page 103 Simrad SC90 Installation Manual ...
Страница 542: ... 2018Kongsberg Maritime ISBN xxx ...
Страница 543: ......
Страница 544: ...Simrad SC90 Fish finding sonar Installation Manual ...