Data Rebuilding Operation

Front Panel Storage

FSR202

20

Hot-swap and auto rebuilding features
Off-line back up: When the data is stored in FSR202, user can remove one of the hard drives as back up drive for data such as system operation file, secured 
files, seldom modified files or image and music files.  User can periodically insert hard drive back into FSR202 to execute automatic backup to protect system 
from being hit by computer virus or to avoid the risk of having both hard drives failing at the same time.
When one of the two hard drives fails in FSR202, hard drive failure alerts will show up in both LCD display and the monitoring software. User can remove the 
failed hard drive from the system while the system is still in operation without shutting down. If the failed hard drive is replaced shortly, the system will 
automatically execute the Auto Rebuilding function without affecting the system operation and also any operation command from the user.
When FSR202 detects one hard drive missing or failed, the Buzzer will start BEEPING with the
1. LCD displaying the following message:
2. After replacing a new hard drive with the failed one, LCD will display the following messages :
3. A few seconds after inserting a new hard drive, LCD will display the data rebuilding progress :
4. When FSR202 completes its rebuilding, LCD should display the following message :

Hot-Swap und automatische Wiederherstellung
Offline-Sicherung: Wenn Daten im FSR202 gespeichert sind, können Sie eine der Festplatten als Sicherungsfestplatten für Daten, wie Systembetriebsdateien, 
gesicherte Dateien, selten modifizierte Dateien oder Bild- und Musikdateien, herausnehmen.  Sie können Festplatten regelmäßig wieder in den FSR202 
einsetzen und zum Schutz des Systems vor Computerviren oder zur Vermeidung der Gefahr eines gleichzeitigen Ausfalls beider Festplatten automatische 
Sicherungen durchführen.
Wenn eine der beiden Festplatten im FSR202 ausfällt, erscheinen Alarmmeldungen auf dem LCD-Display und in der Überwachungssoftware. Sie können die 
ausgefallene Festplatte bei laufendem Betrieb aus dem System entfernen, ohne es herunterfahren zu müssen. Falls die ausgefallene Festplatte zeitnah ersetzt 
wird, führt das System automatisch eine automatische Wiederherstellung durch, ohne den Systembetrieb oder Nutzerbefehle zu beeinträchtigen.
1. Wenn der FSR202 erkennt, dass eine Festplatte fehlt oder ausgefallen ist, beginnt der Summer zu piepen und folgende Meldung erscheint auf dem LCD:
2. Nach Auswechslung einer ausgefallenen Festplatte zeigt das LCD folgende Meldung:
3. Einige Sekunden nach Einsetzen einer neuen Festplatte zeigt das LCD den Fortschritt der Datenwiederherstellung an:
4. Nach der Wiederherstellung sollte das LCD folgende Meldung anzeigen:

Cambio en caliente y características de reconstrucción
Copia de seguridad fuera de línea: Cuando los datos se almacenan en el FSR202, el usuario puede retirar uno de los discos duros como disco de copia de 
seguridad de datos como el archivo de funcionamiento del sistema, archivos seguros, archivos raramente modificados o archivos de imágenes y música. El 
usuario puede insertar de forma periódica el disco duro de nuevo en el FSR202 para ejecutar una copia de seguridad automática para proteger al sistema de 
un ataque de un virus de ordenador o para evitar los riesgos de que ambos discos duros fallen a la vez.
Cuando uno o dos discos duros fallen en el FSR202, aparecerán alertas de fallo de disco duro en la pantalla LCD y el programa de control. El usuario puede 
extraer el disco duro con fallos del sistema mientras el sistema todavía está en funcionamiento sin apagarlo. Si el disco duro con fallos se reemplaza en poco 
tiempo, el sistema ejecutará de forma automática la función de Auto Reconstrucción sin afectar el funcionamiento del sistema y tampoco cualquier comando 
del usuario.
1. Cuando el FSR202 detecta que falta o falla un disco duro, el indicador acústico empezará a PITAR mientras el LCD muestra el siguiente mensaje:
2. Tras reemplazar el disco duro con fallo por un nuevo disco duro, el LCD mostrará los siguientes mensajes:
3. Unos segundos después de insertar un nuevo disco duro, el LCD mostrará el progreso de reconstrucción de los datos:
4. Cuando el FSR202 completa su reconstrucción, el LCD mostrará el siguiente mensaje:

Echange à chaud et fonction de reconstruction automatique
Sauvegarde hors ligne: Lorsque des données sont stockées sur la baie FSR202, l’utilisateur peut retirer l’un des supports de stockage, utilisé pour sauvegarder 
des données importantes du système, des fichiers sécurisés, des photos ou des fichiers audio. Ce support peut être réinséré dans la baie FSR202 pour une 
sauvegarde automatique ou pour éviter que les deux supports de stockage subissent une défaillance en même temps.
Lorsque l’un des deux supports de stockage insérés dans la baie FSR202 est défaillant, une alerte s’affiche sur l’écran LCD et dans le logiciel de contrôle. 
L’utilisateur peut retirer le support défaillant sans éteindre le système au préalable. Si le support est remplacé rapidement, le système lancera la fonction de 
reconstruction automatique du volume sans affecter les opérations effectuées par l’utilisateur.
1. Lorsque la baie FSR202 détecte qu’un support de stockage est manquant ou défaillant, le haut-parleur commencera à émettre un signal sonore et l’écran 
    LCD affichera le message ci-dessous:
2. Après le remplacement du support défaillant, l’écran LCD affiche les messages ci-dessous:
3. Quelques secondes plus tard, l’écran LCD affiche l’état de la phase de reconstruction du volume: 
4. Lorsque la reconstruction du volume est complète, le message ci-dessous s’affiche:

RAID-1 degraded
Pri  : X Sec  : O

1.

Pri HDD : OK 
Sec HDD : OK

4.

2.

3.

Pri HDD : OK 
Sec HDD : Insert

Pri HDD : Insert
Sec HDD : OK

Rebuilding
Sec 

 Pri 32%

Rebuilding
Pri 

 Sec 32%

Содержание SST-FSR202

Страница 1: ...Front Panel Storage 5 25 bay to dual 2 5 SATA 6 Gbit s hot swap cage with RAID 0 and 1 FSR202 dual 2 5 SATA 6 Gbit s hot swap cage...

Страница 2: ...wnloaded from our website at Warranty Information Installation and system optimization guide Packaging Contents Introduction Package Contents And Product Views Product View Front And Back Operation In...

Страница 3: ...lent heat dissipation Compatible with all 2 5 drives up to 15mm thickness Fully supports SATA Hot Swap function Model No Color Material Form factor Drive support Transfer rate Controller Driver interf...

Страница 4: ...netek com Los productos est n sujetos a cambios sin previo aviso Si tiene alguna pregunta acerca de los productos de FSR202 o le gustar a conocer la ltima informaci n sobre un producto actualizaci n d...

Страница 5: ...pr sent dans l emballage et qu aucun l ment n est manquant ou endommag Si un ou plusieurs l ments sont manquants ou endommag s veuillez contacter SilverStone ou votre distributeur revendeur agr FSR20...

Страница 6: ...232 x 1 RS232 1 SATA 1 x 2 x 3 P x 1 FSR202 FSR202 x 1 x 2 RS232 x 1 RS232 x 1 SATA x 1 x 2 x 3 x 1 FSR202 FSR202 x 1 x 2 RS232 x 1 RS232 x 1 SATA x 1 x 2 x 3 x 1 SilverStone FSR202 FSR202 x 1 x 2 RS2...

Страница 7: ...teur SATA 7 pin v nement Panne du ventilateur Ne tourne plus Surchauffe 50 oC D faillance du disque dur En attente Formatage acc s aux donn es Reconstruction du volume source Reconstruction du volume...

Страница 8: ...C HDD HDD SSD 1 2 UP DOWN 3 ESC 4 Enter 5 MUTE 6 7 8 9 1 2 3 R232 4 SATA 15 pin 5 SATA 7 pin 50 C 1 2 UP DOWN 3 ESC 4 Enter 5 MUTE 6 7 8 9 1 2 3 R232 4 SATA 15 pin 5 SATA 7 pin 50 C LED 1 LCD 2 3 ESC...

Страница 9: ...nto 10 35 50 59 Temperatura de almacenamiento 20 47 4 116 Voltaje de la l nea 12V 5V DC Temperatura operativa 10 35 50 59 Temperatura d immagazzinamento 20 47 4 116 Tensione corrente 12V 5V DC Temp ra...

Страница 10: ...bweichen 7 Wir empfehlen dringend wichtige Daten im FSR202 regelm ig in der Cloud oder ber ein separates Speicherger t zu sichern SilverStone bernimmt keine Verantwortung f r Datenverluste in Verbindu...

Страница 11: ...prima di effettuare la modifica 1 SATA I SATA II SATAIII 2 SATA I SATA II SATAIII 3 FSR202 RAID 1 4 FSR202 5 6 FSR202 7 FSR202 SilverStone 1 Los ordenadores y servidores deben ser compatibles con SATA...

Страница 12: ...202 FSR202 SilverStone 1 SATA I SATA II SATA III 2 SATA I SATA II SATA III 3 FSR202 RAID RAID 1 4 5 6 FSR202 7 FSR202 FSR202 SilverStone 1 SATA I SATA II SATAIII 2 SATA I SATA II SATAIII 3 FSR202 RAID...

Страница 13: ...estplatten in die herausnehmbaren Festplatteneins tze und befestigen Sie sie mit den im Zubeh rkit enthaltenen Schrauben andernfalls k nnten sie durch versehentliche Ersch tterungen oder Herausfallen...

Страница 14: ...or favor aseg rese de que su dispositivo est bien conectado con una fuente de alimentaci n directa y espec fica para tener una entrada de potencia estable Attenersi alle istruzioni di seguito per comp...

Страница 15: ...orage FSR202 1 2 3 90 1 4 5 6 FSR202 2 1 RS232 RS232 RS232 2 3 1 SilverStone 2 3 1 4 5 6 FSR202 2 1 RS232 RS232 RS232 IPC 2 3 1 SilverStone 2 3 r 1 4 5 6 FSR202 2 1 RS232 RS232 RS232 IPC 2 2 3 1 2 3 9...

Страница 16: ...funcionar correctamente Una vez reemplace el disco duro con fallos por uno nuevo el FSR202 reconstruir los datos de forma autom tica a partir de los datos existentes hacia el disco duro nuevo 2 Modo R...

Страница 17: ...ID 1 1 FSR202 FSR202 2 RAID 1 FSR202 FSR202 2 RAID 0 1 FSR202 FSR202 2 RAID 0 FSR202 RAID RAID 1 RAID 1 1 RAID 1 1 FSR202 FSR202 2 RAID 1 2 RAID 0 1 FSR202 FSR202 2 RAID 0 RAID RAID 1 RAID 1 1 RAID 1...

Страница 18: ...1 El Administrador de Dispositivos de Windows detectar autom ticamente el los disco s duro s 2 Puede escoger formatear el disco duro usando la herramienta Administrador de Dispositivos del sistema op...

Страница 19: ...202 1 Windows 2 FSR202 FSR202 Q A FSR202 FSR202 1 Windows OS 2 FSR202 FSR202 Q A FSR202 BIOS FSR202 1 FSR202 Windows 2 FSR202 FSR202 Q A FSR202 BIOS FSR202 1 FSR202 Windows 2 FSR202 FSR202 Q A FSR202...

Страница 20: ...Estado Arranque 1 1 y Normal 1 2 2 Sobrecalentamiento 50 C 3 Fallo del ventilador 4 RAID 1 Degradado Fallo del disco duro primario pero disco duro 5 Fallo de RAID 1 Fallo de discos duros primario y s...

Страница 21: ...sono rilevate come primarie per un array RAID 7 RAID 0 guasto Disco rigido primario mancante ma disco rigido secondario normale 8 Ricostruzione 1 1 1 1 2 2 50 C 3 4 RAID 1 5 RAID 1 6 RAID 1 RAID 7 RA...

Страница 22: ...trucci n Copia de seguridad fuera de l nea Cuando los datos se almacenan en el FSR202 el usuario puede retirar uno de los discos duros como disco de copia de seguridad de datos como el archivo de func...

Страница 23: ...do guasto viene sostituito a breve il sistema esegue automaticamente la funzione Ricostruzione automatica senza influire sul funzionamento del sistema e qualsiasi comando operativo da parte dell utent...

Страница 24: ...es descargable desde la p gina web de SilverStone 1 Estado del sistema Este GUI detecta autom ticamente su FSR202 y revela la informaci n relativa correspondiente possibile installare il software GUI...

Страница 25: ...archivo de firmware para proceder Tras completar la actualizaci n puede reiniciar la unidad para trabajar con el nuevo firmware Advertencia Cualquier actualizaci n de firmware aleatoria podr a hacer q...

Страница 26: ...de SMTP Login Authentication y teclee la contrase a de la direcci n de correo electr nico 3 Cuando complete la configuraci n haga clic en el bot n OK para guardar El FSR202 debe estar conectado y func...

Страница 27: ...columna de Tema y Contenidos 3 Cuando se complete la configuraci n haga clic en el bot n OK para guardar El FSR202 debe estar conectado y operacional durante la configuraci n del GUI 3 2 HDD guasto di...

Страница 28: ...Front Panel Storage FSR202 26 4 The GUI Management Software Version 4 Die Managementsoftwareversion 4 Versi n de software del GUI de Gesti n 4 Versione software di gestione GUI 4 Version de l utilita...

Страница 29: ...nstrucci n finalice para tener el m ximo rendimiento Si no es as entonces por favor siga las instrucciones siguientes para encontrar las causas posibles 1 Examine si los cables SATA conectados son dem...

Страница 30: ...not increase even if you replace one of the drives with a larger capacity model Q2 Why does error message appear when I installed a second hard drive A The storage capacity of the new replaced hard dr...

Страница 31: ...t di archiviazione non aumenta anche se si sostituisce una delle unit con un modello di capacit superiore D2 Perch appare un messaggio di errore quando si installa un secondo disco rigido R La capacit...

Страница 32: ...ich tun wenn ein RAID 1 Fehler auftritt und Zwei Quellen am Bildschirm angezeigt wird A 1 Legen Sie fest welches Laufwerk als prim res Quelle und welches als sekund res Laufwerk Ziel genutzt werden so...

Страница 33: ...ador 2 Inserte el disco que desea usar como disco fuente en el FSR202 luego saque el otro disco 3 Tras encender el ordenador el nico disco en el FSR202 se configurar autom ticamente como el disco fuen...

Страница 34: ...2 RAID Q4 A 1 2 FSR202 3 FSR202 Q1 FSR202 A RAID 1 FSR202 Q2 A Sector to Sector Source FSR202 target Q3 RAID1 Double Source A 1 Source 2 3 Source 4 Source FSR202 target FR202 FSR202 Rebuilding Q4 Sour...

Страница 35: ...urchase date to determine warranty eligibility 6 If a problem develops during the warranty period please contact your retailer reseller SilverStone authorized distributors or SilverStone http www silv...

Страница 36: ...G11229290...

Отзывы: