+VLS = <label>
Analog Source / Destination Selection
<label>
Description
0
DCE is on-hook. AOUT disabled. Tone detectors disabled.
Si3000 sample pass-through to DAA is inactive.
1
DCE is off-hook. AOUT disabled. Tone detectors disabled.
4
DCE is on-hook. AOUT connected to tone generators.
Tone detectors disabled.
5
DCE is off-hook. AOUT connected to PSTN.
Tone detectors enabled.
13
DCE is off-hook. V.253 tone event reporting enabled. Si3000 sample
pass-through to DAA is active with options for speakerphone
operation.
14
DCE is on-hook. V.253 tone event reporting enabled. Si3000 interface
is active for DTE voice stream pass-through.
15
DCE is off-hook. V.253 tone event reporting enabled. Si3000 sample
pass-through to DAA is active with options for handset operation.
20
DCE is on-hook. AOUT disabled. Tone detectors enabled.
21
DCE is on-hook. AOUT connected to tone generators. Tone detectors
enabled.
Table 131 on page 202 shows the voice-mode operation and the signal paths. See
10.2.4.2 of V.253 for an explanation of the AT +VLS=? command results. If an ATD
command is sent while the DCE is in VLS=0 and +FCLASS=8, the DCE will automati-
cally transition to VLS=1. The ATH command will automatically force the DCE to
VLS=0. The main options of interest are the 0, 13, 14, and 5. The +VLS=0 setting
must be applied first before applying a new +VLS value to ensure the mode is exited
properly.
+VNH = <hook>
Automatic Hangup Control
<hook>
Description
0
The DCE retains automatic hangups as is normal in the other modes
(such as hanging up the phone when the ISOmodem does not detect a data carrier
with a given time interval).
1
The DCE shall disable automatic hangups in the other non-voice
modes.
2
The DCE shall disable all hang-ups in other non-voice modes.
The DCE shall only perform a “logical” hangup (return the OK result
code).
+VRA = <interval>
Ringing Tone Goes Away Timer
The DCE only uses this command in call origination transactions. This command sets
the amount of time in 0.1 second units the DCE shall wait between Ringing Tone
before it can assume that the remote modem has gone off-hook. Default time is five
seconds.
Table 124. Extended AT+ Command Set (Continued)
Command
Action
Содержание Si2404
Страница 2: ...AN93 2 Rev 1 4 ...
Страница 27: ...AN93 Rev 1 4 27 Figure 7 Parallel Interface Read Timing Figure 8 Parallel Interface Write Timing ...
Страница 200: ...AN93 200 Rev 1 4 Figure 31 TAM Handset and Speakerphone Voice Paths ...
Страница 201: ...AN93 Rev 1 4 201 Figure 32 Si3000 Codec Gain and Signal Selection Options ...
Страница 290: ...AN93 290 Rev 1 4 Figure 57 256 Band Spectral Display Figure 58 2048 Band Spectral Display ...
Страница 305: ...AN93 Rev 1 4 305 Figure 76 Parallel or SPI Port Interrupt Service Flowchart ...