AN93
Rev. 1.4
163
6.5. Type II Caller ID/SAS Detection
When a call is in progress, the Subscriber Alerting Signal (SAS) tone is sent by the central office to indicate a
second incoming call. The central office may also issue a CPE Alert Signal (CAS) after the SAS to indicate that call
waiting Caller ID (CWCID) information is available. If properly configured, the modem will acknowledge the CAS
tone, receive the CWCID data, and perform a retrain.
The ISOmodem is configured through the +PCW command to toggle the RI pin (+PCW=0), hang up (+PCW=1), or
do nothing (+PCW=2) upon receipt of the SAS tone. The default is to ignore the SAS tone. The modem, enabled
through the +VCID command, will collect Caller ID information if +PCW is set to toggle the RI pin. The AT:I
command can be used to verify receipt of the SAS and CWCID data. Bit 9 will be set for SAS receipt due to the RI
toggle. Bit 4 will be set if CWCID data are received.
The CWCID data are collected using the +VCIDR? command. The data message is displayed in hexadecimal
format using ASCII text. The modem will return NO DATA if no Caller ID is available. The +VCIDR response is
listed below for the following example CWCID message:
Date & Time:
09/11 16:21
ICLID Number:
512-555-1234
Calling Name:
JOHN_DOE
+VCIDR:
80 20 01 08 30 39 31 31 31 36 32 31 02 0A 35 31
32 35 35 35 31 32 33 34 07 08 4A 4F 48 4E 5F 44
4F 45 40
OK
Table 113 defines the Multiple Data Message Format (MDMF) parameters in the example response.
The SAS tone varies between countries and requires configuration of user registers U9F to UA9. The SAS_FREQ
(U9F) register sets the expected SAS tone frequency as shown in Table 114. The default SAS frequency is 440 Hz.
The expected cadence is set in cadence registers SAS_CADENCE0 (UA0) through SAS_CADENCE9 (UA9).
Table 113. MDMF Parameters
Character Description
Hexadecimal Value
ASCII Value
Message Type (MDMF)
80
Message Length
20
Parameter Type (Date/Time)
01
Parameter Length
08
Month
30 39
09
Day
31 31
11
Hour
31 36
16
Minutes
32 31
21
Parameter Type (Number)
02
Parameter Length
0A
Number
35 31 32 35 35 35 31 32 33 34
5125551234
Parameter Type (Name)
07
Parameter Length
08
Name
4A 4F 48 4E 5F 44 4F 45
JOHN_DOE
Checksum
40
Содержание Si2404
Страница 2: ...AN93 2 Rev 1 4 ...
Страница 27: ...AN93 Rev 1 4 27 Figure 7 Parallel Interface Read Timing Figure 8 Parallel Interface Write Timing ...
Страница 200: ...AN93 200 Rev 1 4 Figure 31 TAM Handset and Speakerphone Voice Paths ...
Страница 201: ...AN93 Rev 1 4 201 Figure 32 Si3000 Codec Gain and Signal Selection Options ...
Страница 290: ...AN93 290 Rev 1 4 Figure 57 256 Band Spectral Display Figure 58 2048 Band Spectral Display ...
Страница 305: ...AN93 Rev 1 4 305 Figure 76 Parallel or SPI Port Interrupt Service Flowchart ...