A N 9 3
64
Rev. 1.4
Caution:
Some U-register addresses are reserved for internal use and hidden from the user. Consequently, there
are gaps in the addresses of available U registers. Writing to reserved registers can cause unpredictable results.
Care must therefore be taken not to write to reserved or undefined register locations. This is especially likely when
writing to consecutive U-register addresses: all addresses covered by a conscutive write operation must be defined
and allowed to the user.
The AT command execution time is as long as 300 ms. The host must wait for a response after each command
(e.g., OK) before issuing additional commands. The reset recovery time (the time between a hardware reset or the
carriage return of an ATZ command and the time the next AT command can be executed) must also be respected,
as described in "2.1.1. Reset Sequence" on page 11.
It is recommended that the host delay a minimum of 100 ms before sending any AT commands after a modem
state change. A modem state change is indicated by the modem responses listed below; thus, the host should
delay the recommended minimum after any of these responses:
NO CARRIER
BUSY
LINE IN USE
NO DIALTONE
In addition, the host can initiate a modem state change with the AT commands listed below. The host should delay
the recommended minimum after the OK response from any of these commands:
ATH0
AT+FCLASS (if changing classes)
AT&T0
AT+VLS
Character Abort
Characters must not be sent between the ATDT command and the protocol message. During this time, the modem
is in a transition between command and data modes. Any characters sent during this time will cause the
connection attempt to fail; this is known as a character abort.
Blind dialing (dialing without waiting for dial tone) is enabled by ATX0, ATX1, and ATX3. Whether or not blind
dialing is enabled, use of the W dial modifier causes the modem to look for a dial tone before dialing the number
string after the W. For example, an AT command string, ATX1 DT 9, W123456<CR>, causes the modem to dial 9
immediately without detecting a dial tone but does not dial 123456 until a dial tone is detected. AT commands and
result codes are listed in Tables 49–54. The default settings are shown in bold.
Table 48. Consecutive U-Register Writes on a Single Line
Command
Result
AT:U00,0078,67EF,C4FA
0x0078 written to U00
0x67EF written to U01
0xC4FA written to U02
Table 49. Basic AT Command Set
Command
Action
$
Display Basic AT command mode settings (see text for details).
Answer incoming call.
Re-execute last command (executes immediately, not preceded by AT
or followed by <CR>)
A
A/
Содержание Si2404
Страница 2: ...AN93 2 Rev 1 4 ...
Страница 27: ...AN93 Rev 1 4 27 Figure 7 Parallel Interface Read Timing Figure 8 Parallel Interface Write Timing ...
Страница 200: ...AN93 200 Rev 1 4 Figure 31 TAM Handset and Speakerphone Voice Paths ...
Страница 201: ...AN93 Rev 1 4 201 Figure 32 Si3000 Codec Gain and Signal Selection Options ...
Страница 290: ...AN93 290 Rev 1 4 Figure 57 256 Band Spectral Display Figure 58 2048 Band Spectral Display ...
Страница 305: ...AN93 Rev 1 4 305 Figure 76 Parallel or SPI Port Interrupt Service Flowchart ...