Chapter 2: About the Script Commands
25
Statement data is in the form of:
Parameter = value (such as
raidLevel=5
)
Parameter-name (such as
batteryInstallDate
)
Operation-name (such as
redundancyCheck
)
A user-defined entry (such as user label) is called a variable. In the syntax, it is shown
in italic (such as
trayID
or
volumeGroupName
).
Synopsis of the
Script
Commands
Because you can use the script commands to define and manage the different aspects
of a storage array (such as host topology, drive configuration, controller
configuration, volume definitions, and volume group definitions), the actual number
of commands is extensive. The commands, however, fall into general categories that
are reused when you apply the commands to the different tasks to configure or
maintain a storage array. The following table lists the general form of the script
commands and a definition of each command.
Table 3 General Form of the Script Commands
snapshot
(legacy)
Volume user label
storageArray
Not applicable
tray
Tray ID
volume
Volume user label or volume World Wide Identifier
(WWID) (
set
command only)
volumeCopy
Target volume user label and, optionally, the source
volume user label
volumeGroup
User label
Valid characters are alphanumeric, a hyphen, and an
underscore.
Object Type
Identifier
Syntax
Description
accept
object
{
statement-data
}
Perform the pending operation.
activate
object
{
statement-data
}
Sets up the environment so that an operation can take
place or performs the operation if the environment is
already set up correctly.
autoConfigure storageArray
{
statement-data
}
Automatically creates a configuration that is based on
the parameters that are specified in the command.
Содержание InfiniteStorage 4000 Series
Страница 34: ...22 ExitStatus ...
Страница 48: ...36 Adding Comments to a Script File ...
Страница 110: ...98 Starting Stopping and Resuming a Snapshot Legacy Rollback ...
Страница 168: ...156 Interaction with Other Premium Features ...
Страница 182: ...170 Interaction with Other Premium Features ...
Страница 192: ...180 SSD Cache Management Tasks ...
Страница 216: ...204 RecoveryOperations ...
Страница 218: ...206 Show Storage Array ...
Страница 219: ...Appendix A Examples of Information Returned by the Show Commands 207 ...
Страница 220: ...208 Show Storage Array ...
Страница 221: ...Appendix A Examples of Information Returned by the Show Commands 209 ...
Страница 222: ...210 Show Storage Array ...
Страница 223: ...Appendix A Examples of Information Returned by the Show Commands 211 ...
Страница 224: ...212 Show Storage Array ...
Страница 225: ...Appendix A Examples of Information Returned by the Show Commands 213 ...
Страница 226: ...214 Show Storage Array ...
Страница 227: ...Appendix A Examples of Information Returned by the Show Commands 215 ...
Страница 228: ...216 Show Storage Array ...
Страница 229: ...Appendix A Examples of Information Returned by the Show Commands 217 ...
Страница 230: ...218 Show Storage Array ...
Страница 231: ...Appendix A Examples of Information Returned by the Show Commands 219 ...
Страница 233: ...Appendix A Examples of Information Returned by the Show Commands 221 ...
Страница 234: ...222 Show Controller NVSRAM ...
Страница 252: ...240 ShowDrive Show Drive The show drive command returns information about the drives in a storage array ...
Страница 253: ...Appendix A Examples of Information Returned by the Show Commands 241 ...
Страница 254: ...242 ShowDrive ...
Страница 255: ...Appendix A Examples of Information Returned by the Show Commands 243 ...
Страница 256: ...244 ShowDrive ...
Страница 257: ...Appendix A Examples of Information Returned by the Show Commands 245 ...
Страница 258: ...246 ShowDrive ...
Страница 268: ...256 ConfigurationUtility ...
Страница 275: ......
Страница 276: ...Copyright 2012 NetApp Inc All rights reserved ...