76
Modifying Your Configuration
set (allVolumes | volume [
volumeName
] |
volumes [
volumeName1
...
volumeNameN
]
volume <
wwID
>) |
cacheFlushModifier=
cacheFlushModifierValue
|
cacheWithoutBatteryEnabled=(TRUE | FALSE) |
mirrorCacheEnabled=(TRUE | FALSE) |
readCacheEnabled=(TRUE | FALSE) |
writeCacheEnabled=(TRUE | FALSE) |
cacheReadPrefetch=(TRUE | FALSE)
The
cacheFlushModifier
parameter defines the amount of time that data stays
in the cache before it is written to the drives. The following table lists the values for
the
cacheFlushModifier
parameter.
Table 13 Values for the
cacheFlushModifier
Parameter
This example shows how to set this parameter value for all of the volumes in the
storage array:
c:\...\sm
X
\client>smcli 123.45.67.88 123.45.67.89
-c “set allvolumes cacheFlushModifier=10;”
Value
Meaning
Immediate
Data is flushed as soon as it is placed into the cache.
250
Data is flushed after 250 ms.
500
Data is flushed after 500 ms.
750
Data is flushed after 750 ms.
1
Data is flushed after 1 s.
1500
Data is flushed after 1500 ms.
2
Data is flushed after 2 s.
5
Data is flushed after 5 s.
10
Data is flushed after 10 s.
20
Data is flushed after 20 s.
60
Data is flushed after 60 s (1 min.).
120
Data is flushed after 120 s (2 min.).
300
Data is flushed after 300 s (5 min.).
1200
Data is flushed after 1200 s (20 min.).
3600
Data is flushed after 3600 s (1 hr.).
Infinite
Data in cache is not subject to any age or time constraints. The
data is flushed based on other criteria managed by the
controller.
Содержание InfiniteStorage 4000 Series
Страница 34: ...22 ExitStatus ...
Страница 48: ...36 Adding Comments to a Script File ...
Страница 110: ...98 Starting Stopping and Resuming a Snapshot Legacy Rollback ...
Страница 168: ...156 Interaction with Other Premium Features ...
Страница 182: ...170 Interaction with Other Premium Features ...
Страница 192: ...180 SSD Cache Management Tasks ...
Страница 216: ...204 RecoveryOperations ...
Страница 218: ...206 Show Storage Array ...
Страница 219: ...Appendix A Examples of Information Returned by the Show Commands 207 ...
Страница 220: ...208 Show Storage Array ...
Страница 221: ...Appendix A Examples of Information Returned by the Show Commands 209 ...
Страница 222: ...210 Show Storage Array ...
Страница 223: ...Appendix A Examples of Information Returned by the Show Commands 211 ...
Страница 224: ...212 Show Storage Array ...
Страница 225: ...Appendix A Examples of Information Returned by the Show Commands 213 ...
Страница 226: ...214 Show Storage Array ...
Страница 227: ...Appendix A Examples of Information Returned by the Show Commands 215 ...
Страница 228: ...216 Show Storage Array ...
Страница 229: ...Appendix A Examples of Information Returned by the Show Commands 217 ...
Страница 230: ...218 Show Storage Array ...
Страница 231: ...Appendix A Examples of Information Returned by the Show Commands 219 ...
Страница 233: ...Appendix A Examples of Information Returned by the Show Commands 221 ...
Страница 234: ...222 Show Controller NVSRAM ...
Страница 252: ...240 ShowDrive Show Drive The show drive command returns information about the drives in a storage array ...
Страница 253: ...Appendix A Examples of Information Returned by the Show Commands 241 ...
Страница 254: ...242 ShowDrive ...
Страница 255: ...Appendix A Examples of Information Returned by the Show Commands 243 ...
Страница 256: ...244 ShowDrive ...
Страница 257: ...Appendix A Examples of Information Returned by the Show Commands 245 ...
Страница 258: ...246 ShowDrive ...
Страница 268: ...256 ConfigurationUtility ...
Страница 275: ......
Страница 276: ...Copyright 2012 NetApp Inc All rights reserved ...