DIAS-DRIVE 335-23
Page 38
27.09.2017
3.3
DC-link (X1B)
To bridge the DC-link voltage with other servo amplifiers, the X1B/2 (+DC) and 3 (-DC)
connectors can be used.
The intermediate circuit power can be distributed to different servo amplifiers with this
method.
Note:
If the intermediate circuit is bridged within a group of amplifiers,
the main power supply in this group must also be bridged.
3.4
External Regen Resistor (X1B)
If the power of the internal brake resistor is insufficient, an external resistor can be added.
Here, the connection to R
int
(terminal 4 of X1B) and R
tr
(terminal 5 of X1B) must be
removed. The external resistor is connected to terminal 2 and 5 of X1B. The fuse on both
connections of the external brake resistor is mandatory. 1000 VDC fuses with slow trigger
characteristics must be used.
Note: The brake resistor fuse does not protect the resistor, rather the
connected cable in the event of a short circuit. The amplifier has
electronic protection for the brake resistor.
Содержание DIAS-Drive 335-23
Страница 1: ...DIAS Drive 335 23 Date of creation 01 10 2013 Current version 27 09 2017 Article No 10 501 351 23E...
Страница 12: ...DIAS DRIVE 335 23 Page 10 27 09 2017 1 3 Servo Amplifier Components...
Страница 17: ...DIAS DRIVE 335 23 27 09 2017 Page 15 1 8 Block Diagram...
Страница 62: ...DIAS DRIVE 335 23 Page 60 27 09 2017 6 2 2 Dimensions incl Mounting Set...
Страница 67: ...DIAS DRIVE 335 23 27 09 2017 Page 65 7 2 Mechanical Dimensions Integrated into the SDD3xx servo amplifier...
Страница 82: ...DIAS DRIVE 335 23 Page 80 27 09 2017...
Страница 94: ...DIAS DRIVE 335 23 Page 92 27 09 2017...