![SIGMATEK DIAS-Drive 335-23 Скачать руководство пользователя страница 76](http://html1.mh-extra.com/html/sigmatek/dias-drive-335-23/dias-drive-335-23_manual_1268155076.webp)
DIAS-DRIVE 335-23
Page 74
27.09.2017
7.6.1.2 Function
The safety functions in the DIAS Drive are controlled over two digital inputs.
The following table shows the status that the ENABLE_L and ENABLE_H inputs must
assume to enable normal operation or trigger the safety function.
Input Status
Relay output S3/S4
Description
ENABLE_L
ENABLE_H
Open
Open
When the servo amplifier is
supplied with 24 V, the
inputs are closed after a
minimum delay 0.4 of
seconds and a maximum of
1 seconds
Safe status of the drive system
Low
Low
When the servo amplifier is
supplied with 24 V, the
inputs are closed after a
minimum delay 0.4 of
seconds and a maximum of
1 seconds
•
Single channel safe status, only
when
using
classic
I/O
technology
•
Safe status of the drive
system
, when a safe output is
used by a Safety PLC. Also
when ENABLE_L is connected
to
„Ext. GND“
Low
Open
Low
High
Open
Drive system ready
Содержание DIAS-Drive 335-23
Страница 1: ...DIAS Drive 335 23 Date of creation 01 10 2013 Current version 27 09 2017 Article No 10 501 351 23E...
Страница 12: ...DIAS DRIVE 335 23 Page 10 27 09 2017 1 3 Servo Amplifier Components...
Страница 17: ...DIAS DRIVE 335 23 27 09 2017 Page 15 1 8 Block Diagram...
Страница 62: ...DIAS DRIVE 335 23 Page 60 27 09 2017 6 2 2 Dimensions incl Mounting Set...
Страница 67: ...DIAS DRIVE 335 23 27 09 2017 Page 65 7 2 Mechanical Dimensions Integrated into the SDD3xx servo amplifier...
Страница 82: ...DIAS DRIVE 335 23 Page 80 27 09 2017...
Страница 94: ...DIAS DRIVE 335 23 Page 92 27 09 2017...