Get the trigger mode
Parameter
Type
Enumeration
Parameter
Range
AUTO|KEY|BUS|EXT
Return
Enumeration
Default
AUTO
Menu
SWEEP > Trigger Mode
Example
:SWEep:SWEep:TRIGger:TYPE KEY
3.6.3.25
Point Trigger ([:SOURce]:SWEep:POINt:TRIGger:TYPE)
Command
Format
[:SOURce]:SWEep:POINt:TRIGger:TYPE AUTO|KEY|BUS|EXT
[:SOURce]:SWEep:POINt:TRIGger:TYPE?
Instruction
Select the point trigger
Get the point trigger
Parameter
Type
Enumeration
Parameter
Range
AUTO|KEY|BUS|EXT
Return
Enumeration
Default
AUTO
Menu
SWEEP > Point Trigger
Example
:SWEep:POINt:TRIGger:TYPE KEY
3.6.3.26
Trigger Slope ([:SOURce]:INPut:TRIGger:SLOPe)
Command
Format
[:SOURce]:INPut:TRIGger:SLOPe POSitive|NEGative
[:SOURce]:INPut:TRIGger:SLOPe?
Instruction
Select the trigger slope
Get the trigger slope
Parameter
Type
Enumeration
Parameter
Range
POSitive|NEGative
Return
Enumeration