96 SSG5000X Programming Guide
Format
[:SOURce]:RADio:CUSTom:FILTer?
Instruction
This command specifies the Real-Time Modulation filter type
Parameter
Type
Enumeration
Parameter
Range
NONE|RAISecosine|ROOTcosine|GAUSsian
Return
Enumeration
Default
ROOTcosine
Menu
Custom > Filter > Filter Type
Example
:RADio:CUSTom:FILTer GAUSsian
3.8.1.17
Filter Alpha ([:SOURce]:RADio:CUSTom:ALPHa)
Command
Format
[:SOURce]:RADio:CUSTom:ALPHa <val>
[:SOURce]:RADio:CUSTom:ALPHa?
Instruction
This command changes the Nyquist or root Nyquist filter’s alpha value or
Caussian’s BT value
Parameter
Type
Float
Parameter
Range
0.010 ~ 1.000
Return
Float
Default
0.35
Menu
Custom > Filter > Filter Alpha
Example
:RADio:CUSTom:ALPHa 0.22
3.8.1.18
Filter Length ([:SOURce]:RADio:CUSTom:FILTer:LENGth)
Command
Format
[:SOURce]:RADio:CUSTom:FILTer:LENGth <len>
[:SOURce]:RADio:CUSTom:FILTer:LENGth?
Instruction
This command changes the length of filter
Parameter
Type
Integer
Parameter
Range
1 ~ 512
Return
Integer