SIGLENT
SSG5000X Programming Guide 107
Default
AUTO
Menu
ARB > ARB Setup > Modulator Atten Type
Example
:RADio:ARB:IQ:MODulation:ATTen:AUTO AUTO
3.8.4.6
Modulation Atten
([:SOURce]:RADio:ARB:IQ:MODulation:ATTen)
Command
Format
[:SOURce]:RADio:ARB:IQ:MODulation:ATTen <val>
[:SOURce]:RADio:ARB:IQ:MODulation:ATTen?
Instruction
This command sets the attenuation level of the I/Q signals being
modulated through the signal generator RF path
Parameter
Type
Float
Parameter
Range
0 ~ 20
Return
Float
Default
6
Menu
ARB > ARB Setup > Modulation Atten
Example
:RADio:ARB:IQ:MODulation:ATTen 10
3.8.4.7
Real Time AWGN ([:SOURce]:RADio:ARB:NOISe[:STATe])
Command
Format
[:SOURce]:RADio:ARB:NOISe[:STATe] ON|OFF|1|0
[:SOURce]:RADio:ARB:NOISe[:STATe]?
Instruction
This command enables or disables adding real-time additive white
gaussian noise (AWGN) to the carrier modulated by the waveform being
played by the dual ARB waveform player
Parameter
Type
Boolean
Parameter
Range
ON|OFF|1|0
Return
Boolean
Default
0
Menu
ARB > ARB Setup > Real Time AWGN
Example
:RADio:ARB:NOISe 1