SIGLENT
SSG5000X Programming Guide 115
Instruction
This command shifts the marker points for all markers in a waveform
segment earlier or later by the value of the <rotate_count> variable
Parameter
Type
String, Integer
Parameter
Range
None, -(n - 1) to (n - 1). n = number of points in the waveform
Return
None
Default
None
Menu
None
Example
:RADio:ARB:MARKer:ROTate “SINE_WAVE”,10
3.8.4.25
Set Marker ([:SOURce]:RADio:ARB:MARKer:[SET])
Command
Format
[:SOURce]:RADio:ARB:MARKer:[SET]
"<file_name>",<marker>,<first_point>,<last_point>,<skip_count>
Instruction
This command sets a single marker point or a range of marker points on a
waveform segment for the selected marker (1
–
4)
Parameter
Type
String, Integer, Integer, Integer, Integer
Parameter
Range
None, 1 ~ 4, 1 ~ point of <file_name>, <first_point> ~ point of <file_name>,
0 ~ <last_point> - <first_point>
Return
None
Default
None
Menu
None
Example
:RADio:ARB:MARKer “SINE_WAVE”,1,10,20,5
3.8.4.26
Marker Polarity
([:SOURce]:RADio:ARB:MPOLarity:MARKer1|2|3|4)
Command
Format
[:SOURce]:RADio:ARB:MPOLarity:MARKer1|2|3|4 NEG|POS
[:SOURce]:RADio:ARB:MPOLarity:MARKer1|2|3|4?
Instruction
This command sets the polarity for the selected marker. For a positive
marker polarity, the marker signal is high during the marker points. For a
negative marker polarity, the marker signal is high during the period of no
marker points
Parameter Enumeration