Installing/mounting
4.2 Installation location requirements
SITRANS LR250 with FOUNDATION FIELDBUS
24
Operating Instructions, 09/2021, A5E32221411-AH
4.2
Installation location requirements
WARNING
Aggressive atmospheres
Danger to personnel, system and environment can result from unsuitable environment.
•
Provide an environment suitable to the housing rating and materials of construction.
NOTICE
Direct sunlight
Damage to device.
The device can overheat or materials become brittle due to UV exposure.
•
Protect the device from direct sunlight.
•
Make sure that the maximum permissible ambient temperature is not exceeded. Refer to
the information in Environmental (Page 182).
①
Ambient temperature
②
Device nameplate
③
Device tag
④
Process temperature (at process connection)
⑤
Process connection tag (contains process connection related information)
Antenna
①
④
Horn
-40 to +80 °C
(-40 to +176 °F)
with FKM O-ring:-40 to +200 °C (-40 to
392 °F)
with FFKM O-ring:-20 to +200 °C (-4 to
+392 °F)
PVDF and alumi-
num/polypropylene lens
versions
-40 to +80 °C
(-40 to +176 °F)
-40 to +80 °C
(-40 to +176 °F)
Содержание SITRANS L
Страница 258: ...LCD menu structure SITRANS LR250 with FOUNDATION FIELDBUS 258 Operating Instructions 09 2021 A5E32221411 AH ...
Страница 259: ...LCD menu structure SITRANS LR250 with FOUNDATION FIELDBUS Operating Instructions 09 2021 A5E32221411 AH 259 ...
Страница 260: ...LCD menu structure SITRANS LR250 with FOUNDATION FIELDBUS 260 Operating Instructions 09 2021 A5E32221411 AH ...