Table 8-12
Recommended Control Supply Module
Rated output cur‐
rent [A]
Phases
Input voltage range [V]
Short-circuit current [A]
Article number
20
3
3 AC 380 -10 % (-15 % < 1 min) to
3 AC 480 +10 %
DC 300 … 800
< 24
6SL3100-1DE22-0AA.
WARNING
Hazardous voltage when connecting an unsuitable power supply
If a power supply is connected that is not suitable, parts and components of the device could
be live (under voltage). Touching live components can result in death or severe injury.
• Connect the ground potential to the protective conductor connection.
• Mount the power supply close to the drive lineup.
Ideally, they should be mounted on a common mounting plate. If different mounting plates
are used, they must be electrically connected in compliance with the Configuration Manual,
"EMC installation guideline".
Control cabinet design and EMC booksize
8.8 24 V DC supply voltage
Booksize power units
Equipment Manual, 01/2022, 6SL3097-6AC30-0BP0
131