![Siemens SIMATIC RF300 Скачать руководство пользователя страница 396](http://html.mh-extra.com/html/siemens/simatic-rf300/simatic-rf300_system-manual_374416396.webp)
8.26
MDS D524
8.26.1
Characteristics
MDS D524
Characteristics
Area of application
Production automation as well use in assembly and
manufacturing lines
Memory size
8192 bytes of FRAM user memory
Write/read range
See section "Field data of ISO transponders (MDS D)
(Page 53)."
Mounting on metal
Yes, with spacer
ISO standard
ISO 15693
Degree of protection
IP67/IPx9K
8.26.2
Ordering data
Table 8-69
Ordering data for MDS D524
Article number
MDS D524
6GT2600-5AC00
Table 8-70
Ordering data of MDS D524 accessories
Article number
Spacer
6GT2690-0AK00
8.26.3
Mounting on metal
Direct mounting of the transponder on metal is not permitted. A distance of ≥ 20 mm is
recommended to avoid a reduced read/write range and a reduction of the field data. This can be
accomplished, for example, by installing a spacer.
Note that if the distances (a and h) are not observed, this may result in a reduction of the field
data as well as a reduced write/read range.
ISO transponder
8.26 MDS D524
SIMATIC RF300
396
System Manual, 02/2021, C79000-G8976-C345-09
Содержание SIMATIC RF300
Страница 14: ...Table of contents SIMATIC RF300 14 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 18: ...Introduction 1 1 Preface SIMATIC RF300 18 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 22: ...Safety information 2 1 Security information SIMATIC RF300 22 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 208: ...Readers 5 6 SIMATIC RF382R with Scanmode 1st generation SIMATIC RF300 208 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 258: ...Antennas 6 10 ANT 30 stainless steel variant SIMATIC RF300 258 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 474: ...Service Support SIMATIC RF300 474 System Manual 02 2021 C79000 G8976 C345 09 ...