5.5.7
Minimum distance between RF380R readers
RF380R side by side
'
'
6,0$7,&
5)5
6,0$7,&
5)5
6,0$7,&
5)5
D
≥ 400 mm (with 2 readers)
≥ 500 mm (with more than 2 readers)
Figure 5-20
Minimum distance between several RF380R
RF380R face-to-face
'
D ≥ 800 mm
Figure 5-21
Face-to-face distance between two RF380R
5.5.8
Using the reader in hazardous area
WARNING
Risk of explosion
In a flammable or combustible environment, no cables may be connected to or disconnected
from the device.
Readers
5.5 SIMATIC RF380R