Using the reader in hazardous area for dust
The equipment is suitable for dusts whose ignition temperatures for a dust layer of 5 mm are
higher than 80 °C (smoldering temperature).
Ambient temperature range
Temperature value
-25 °C < Ta < +70 °C
T80 °C
WARNING
Ignitions of dust-air mixtures
When using the reader, check to make sure that the temperature values are adhered to in
keeping with the requirements of the area of application. Non-compliance with the permitted
temperature range while using the reader can lead to ignitions of dust-air mixtures.
Installation and operating conditions for hazardous areas:
NOTICE
Risk of explosion
Risk of explosion of dust-air mixtures or gas-air mixtures. Observe the following conditions
when installing and operating the device in a hazardous area in order to avoid a risk of
explosion and damage to the device:
• Making and breaking of circuits is permitted only in a de-energized state.
• The maximum surface temperature, corresponding to the marking, applies only for
operation without a cover of dust.
• The device may only be operated in such a way that adequate protection against UV light is
ensured.
• The device may not be operated in areas influenced by processes that generate high
electrostatic charges.
• The device should only be cleaned with a damp cloth.
• The device must be set up and installed in such a way that it is mechanically protected.
• The grounding of the plug (8-pin) on the reader must be via its supply cable.
• The device may only be operated with accessories specified or supplied by the
manufacturer. All the points above also apply to the accessories (cables and connectors)
and to the antennas (exception: the housing of ANT 1 does not need to be installed with
impact protection).
• The device sockets incl. the metal parts of the connecting cable must have a shrink-on sleeve
pulled over them, in other words, all metal parts apart from the securing sockets of the
housing must be fully covered and be inaccessible.
• After removing the connections (antenna cable, signal/supply cable), the connectors must
be checked for contamination and, if necessary, cleaned before being inserted again.
Readers
5.3 SIMATIC RF340R/RF350R
SIMATIC RF300
154
System Manual, 02/2021, C79000-G8976-C345-09
Содержание SIMATIC RF300
Страница 14: ...Table of contents SIMATIC RF300 14 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 18: ...Introduction 1 1 Preface SIMATIC RF300 18 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 22: ...Safety information 2 1 Security information SIMATIC RF300 22 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 208: ...Readers 5 6 SIMATIC RF382R with Scanmode 1st generation SIMATIC RF300 208 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 258: ...Antennas 6 10 ANT 30 stainless steel variant SIMATIC RF300 258 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 474: ...Service Support SIMATIC RF300 474 System Manual 02 2021 C79000 G8976 C345 09 ...