![Siemens SIMATIC RF300 Скачать руководство пользователя страница 128](http://html.mh-extra.com/html/siemens/simatic-rf300/simatic-rf300_system-manual_374416128.webp)
ISO 14443 functionality
You can use ISO 14443 transponders with all readers of the 2nd generation of the RF300 family
- except the RF360R. The 2nd generation RF300 readers thus replace the MOBY E-Reader SLG 72
and SLG 75. Note that the readers for RF300, ISO 15963 or ISO 14443 operation must have
parameters assigned. The parameter assignment done with the aid of the RESET frame (INIT-
Run).
The following commands are supported by the 2nd generation readers in ISO 14443 operation:
• READ
• WRITE
• MDS-STATUS (mode 3)
• INIT
• REPEAT
Special ISO 14443 commands such as "INCREMENT", "DECREMENT" or "SET-VALUE" are not
supported.
5.1
SIMATIC RF310R
5.1.1
Features
SIMATIC RF310R
Characteristics
Design
①
RS-422 interface
②
LED operating display
Area of application
Identification tasks on small assembly lines in
harsh industrial environments
Readers
5.1 SIMATIC RF310R
SIMATIC RF300
128
System Manual, 02/2021, C79000-G8976-C345-09
Содержание SIMATIC RF300
Страница 14: ...Table of contents SIMATIC RF300 14 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 18: ...Introduction 1 1 Preface SIMATIC RF300 18 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 22: ...Safety information 2 1 Security information SIMATIC RF300 22 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 208: ...Readers 5 6 SIMATIC RF382R with Scanmode 1st generation SIMATIC RF300 208 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 258: ...Antennas 6 10 ANT 30 stainless steel variant SIMATIC RF300 258 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 474: ...Service Support SIMATIC RF300 474 System Manual 02 2021 C79000 G8976 C345 09 ...