Table 4-36
Flush-mounting of transponders and readers
Representation
Description
Non-metallic spacer
Sheet
Metal
Metal
Readers
Problem:
Flush-mounting of transponders and
readers is possible in principle. How‐
ever, the size of the transmission win‐
dow is significantly reduced. The fol‐
lowing measures can be used to
counteract the reduction of the win‐
dow:
10-20 mm
x > 100 mm
Reader
Remedy:
Enlargement of the non-metallic
spacer below the transponder and/or
reader.
The transponder and/or reader are 10
to 20 mm higher than the metal sur‐
round.
(The value x ≥ 100 mm is valid, e.g.
for RF310R. It indicates that, for a dis‐
tance x ≥ 100 mm, the reader can no
longer be significantly affected by
metal.)
a
a
b
b
Reader
Remedy:
Increase the distances a, b to metal.
The following rule of thumb can be
used:
• Increase a, b by a factor of 2 to 3
over the values specified for met‐
al-free areas
• Increasing a, b has a greater ef‐
fect for readers or transponders
with a large limit distance than for
readers or transponders with a
small limit distance.
Mounting of several readers on metal frames or racks
Any reader mounted on metal couples part of the field to the metal frame. There is normally no
interaction as long as the minimum distance D and metal-free areas a, b are maintained.
However, interaction may take place if an iron frame is positioned unfavorably. Longer data
transfer times or sporadic error messages at the communication module are the result.
Note that antenna cables should not be coiled (cable coil = antenna) and should not be mounted
directly on metal when coiled to avoid coupling. Antenna cables should be laid separately in a
Planning the RF300 system
4.3 Installation guidelines
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09
67
Содержание SIMATIC RF300
Страница 14: ...Table of contents SIMATIC RF300 14 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 18: ...Introduction 1 1 Preface SIMATIC RF300 18 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 22: ...Safety information 2 1 Security information SIMATIC RF300 22 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 208: ...Readers 5 6 SIMATIC RF382R with Scanmode 1st generation SIMATIC RF300 208 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 258: ...Antennas 6 10 ANT 30 stainless steel variant SIMATIC RF300 258 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 474: ...Service Support SIMATIC RF300 474 System Manual 02 2021 C79000 G8976 C345 09 ...