![Siemens SIMATIC RF300 Скачать руководство пользователя страница 295](http://html.mh-extra.com/html/siemens/simatic-rf300/simatic-rf300_system-manual_374416295.webp)
WARNING
Ignitions of gas-air mixtures
• When using the RF380T transponder, check that the temperature class is kept to in
conjunction with the requirements of the area of application.
If the temperature ranges are exceeded during use of the transponder, gas-air mixtures may
be ignited.
• The maximum transmit power of the transmitter used to operate the transponder must not
exceed 2 W.
If the transmit power id not kept to, gas-air mixtures may ignite.
7.8.6.2
Installation and operating conditions for the hazardous area
a) Use of the equipment in the vicinity of processes generating high charges is not allowed.
b) The equipment must be mechanically protected when installed.
7.8.7
Technical specifications
Table 7-22
RF380T technical specifications
6GT2800-5DA00
Product type designation
SIMATIC RF380T
Memory
Memory organization
in bytes
Memory configuration
• UID
• 4 bytes EEPROM
• User memory
• 32 KB FRAM
• OTP memory
• 20 bytes EEPROM
Read cycles (at < 40 ℃)
> 10
10
Write cycles (at < 40 ℃)
> 10
10
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
)
Dependent on the reader used, see section "Field
data of RF300 transponders (Page 50)"
Mechanical specifications
Enclosure
• Material
• PPS
• Color
• Anthracite
Recommended distance to metal
≥ 0 mm
RF300 transponder
7.8 SIMATIC RF380T
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09
295
Содержание SIMATIC RF300
Страница 14: ...Table of contents SIMATIC RF300 14 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 18: ...Introduction 1 1 Preface SIMATIC RF300 18 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 22: ...Safety information 2 1 Security information SIMATIC RF300 22 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 208: ...Readers 5 6 SIMATIC RF382R with Scanmode 1st generation SIMATIC RF300 208 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 258: ...Antennas 6 10 ANT 30 stainless steel variant SIMATIC RF300 258 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 474: ...Service Support SIMATIC RF300 474 System Manual 02 2021 C79000 G8976 C345 09 ...