![Siemens SIMATIC RF300 Скачать руководство пользователя страница 177](http://html.mh-extra.com/html/siemens/simatic-rf300/simatic-rf300_system-manual_374416177.webp)
Figure 5-14
Connecting the grounding conductor
5.4.4
Connecting readers
Requirement
Only wire the communication module when the supply voltage is switched off.
Required tools
When using preassembled cables, you need the following tool:
• Torque wrench set (e.g. from Peres; M12/M8, can be set; PER091) for wiring the reader
connections
Note
Using preassembled cables
When connecting the supply voltage, we recommend the cables specified in the section
"Ordering data (Page 462)" (4 x 1.5 mm
2
preassembled).
If you want to make the cable yourself, ensure that the conductor cross-section matches the
system setup or the corresponding protection (1.5 mm
2
).
When using cables that are not preassembled, you need the tool for the specific cable/connector,
for example, an insulation stripper, screwdriver or Allen wrench.
Readers
5.4 SIMATIC RF360R
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09
177
Содержание SIMATIC RF300
Страница 14: ...Table of contents SIMATIC RF300 14 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 18: ...Introduction 1 1 Preface SIMATIC RF300 18 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 22: ...Safety information 2 1 Security information SIMATIC RF300 22 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 208: ...Readers 5 6 SIMATIC RF382R with Scanmode 1st generation SIMATIC RF300 208 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 258: ...Antennas 6 10 ANT 30 stainless steel variant SIMATIC RF300 258 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 474: ...Service Support SIMATIC RF300 474 System Manual 02 2021 C79000 G8976 C345 09 ...