LED
Meaning
PRE_1, PRE_2
Indicates the presence of a transponder.
RxD_1, RxD_2
Indicates live communication with the reader. In the event of a fault on the reader,
this display may also be lit.
On the ASM 475, further operating states are indicated with the LEDs PRE, ERR and SF:
Table 9-6
Operating status display on ASM 475 via LEDs
SF
PRE_1
ERR_1
PRE_2
ERR_2
Meaning
ON
OFF/ON
ON
(perm.)
OFF/ON
ON
(perm.)
Hardware is defective (RAM, Flash, …)
ON
OFF
ON
OFF
OFF
Charger is defective (can only be repaired in
the factory).
OFF
2 Hz
OFF
2 Hz
OFF
Firmware loading is active or no firmware de‐
tected
• Firmware download
• ASM must not be switched off
OFF
2 Hz
2 Hz
2 Hz
2 Hz
Firmware loading
terminated with errors
• Restart required
• Load firmware again
• Check update files
any
5 Hz
5 Hz
5 Hz
5 Hz
Operating system error
• Switch ASM off/on
OFF
OFF
1 flash ev‐
ery 2 s
OFF
1 flash ev‐
ery 2 s
ASM has booted and is waiting for a RESET
(init_run) from the user.
System integration
9.1 ASM 475
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09
419
Содержание SIMATIC RF300
Страница 14: ...Table of contents SIMATIC RF300 14 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 18: ...Introduction 1 1 Preface SIMATIC RF300 18 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 22: ...Safety information 2 1 Security information SIMATIC RF300 22 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 208: ...Readers 5 6 SIMATIC RF382R with Scanmode 1st generation SIMATIC RF300 208 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 258: ...Antennas 6 10 ANT 30 stainless steel variant SIMATIC RF300 258 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 474: ...Service Support SIMATIC RF300 474 System Manual 02 2021 C79000 G8976 C345 09 ...