Identification
The identification is as follows:
0158
II 1 G Ex ia IIC T6 ... T2 Ga
II 1 D Ex ia IIIB T100°C / T135°C / T185°C Da
TÜV 18 ATEX 232450 X
8.7.5.1
Use in hazardous areas for gasses
The temperature class of the transponder for gas explosion hazardous areas depends on the
ambient temperature range as well as the existing reader power or the field strength at the
antenna within the explosion hazardous area.
WARNING
Ignitions of gas-air mixtures
The transponder may only be operated in the ambient temperature range specified for it (see
EC type examination certificate TÜV 18 ATEX 232450 X).
When using the transponder, check to ensure that the temperature class is complied with in
connection with the requirements of the area of application.
Non-compliance with the permitted temperature ranges while using the transponder can lead
to ignitions of gas-air mixtures.
WARNING
Ignitions of gas-air mixtures
The maximum transmit power of the transmitter used to operate the transponder must not
exceed 2 W. The magnetic field strength at the reader antenna must not exceed 5 A/m.
Non-compliance with the permissible transmit power can lead to ignitions of gas-air mixtures.
Temperature class grading for gases and radiated power for 2 W und 5 A/m
If the radiated power of an antenna radiating into the hazardous area or located in the hazardous
area and operating in the 13.56 MHz frequency band cannot exceed the value 2 W or 5 A/m, the
temperature class grading is as follows:
Table 8-19
Temperature class grading for gases
Ambient temperature range
Temperature class
-25 °C ... +220 °C
T2
-25 °C ... +145 °C
T3
-25 °C ... +220 °C
T4
-25 °C ... +95 °C
T5
-25 ℃ ... +30 ℃
T6
ISO transponder
8.7 MDS D139
SIMATIC RF300
324
System Manual, 02/2021, C79000-G8976-C345-09
Содержание SIMATIC RF300
Страница 14: ...Table of contents SIMATIC RF300 14 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 18: ...Introduction 1 1 Preface SIMATIC RF300 18 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 22: ...Safety information 2 1 Security information SIMATIC RF300 22 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 208: ...Readers 5 6 SIMATIC RF382R with Scanmode 1st generation SIMATIC RF300 208 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 258: ...Antennas 6 10 ANT 30 stainless steel variant SIMATIC RF300 258 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 474: ...Service Support SIMATIC RF300 474 System Manual 02 2021 C79000 G8976 C345 09 ...