![Siemens SIMATIC RF300 Скачать руководство пользователя страница 53](http://html.mh-extra.com/html/siemens/simatic-rf300/simatic-rf300_system-manual_374416053.webp)
made. Note that the values "02", "03" and "04" bring about a reduction of the power of
approximately 50%. Settings outside the range (02 ... 08) have the effect of setting the default
value (0.6 W). In this case, there is no error message for reasons of compatibility.
4.2.2
Field data of ISO transponders (MDS D)
The limit distances (S
g
) and operating distances (S
a
) along with the length of the transmission
window for each reader-transponder combination are listed in the tables below.
Observe the following information for field data of ISO transponders:
• A maximum median deviation of ±2 mm is permitted in static mode (without affecting the
field data).
• In dynamic mode, make sure that rectangular transponders cross the antenna field in the
longitudinal direction.
Table 4-10
Field data RF310R reader
Length of the transmission
window (L)
Operating distance (S
a
)
Limit distance (S
g
)
MDS D100
40
2...93
105
MDS D124
30
2...64
72
MDS D126
90
2...65
73
MDS D139
105
5...96
109
MDS D160
30
2...39
44
MDS D165
130
2...90
102
MDS D200
120
2...80
90
MDS D261
80
2...74
83
MDS D324
30
2...47
63
MDS D339
85
5...74
84
MDS D400
90
2...90
105
MDS D423
55
2...35
40
MDS D424
35
1...68
75
MDS D425
30
1...22
25
MDS D426
90
5...75
90
MDS D428
30
1...40
45
MDS D460
30
1...32
38
MDS D524
35
1...70
78
MDS D525
30
1...22
25
MDS D526
90
5...80
90
MDS D528
30
1...43
48
MDS D560
30
1...32
38
All values are in mm
Planning the RF300 system
4.2 Field data for transponders, readers and antennas
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09
53
Содержание SIMATIC RF300
Страница 14: ...Table of contents SIMATIC RF300 14 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 18: ...Introduction 1 1 Preface SIMATIC RF300 18 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 22: ...Safety information 2 1 Security information SIMATIC RF300 22 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 208: ...Readers 5 6 SIMATIC RF382R with Scanmode 1st generation SIMATIC RF300 208 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 258: ...Antennas 6 10 ANT 30 stainless steel variant SIMATIC RF300 258 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 474: ...Service Support SIMATIC RF300 474 System Manual 02 2021 C79000 G8976 C345 09 ...