Glossary
SICAM RTUs, User Manual SICAM CMIC
407
DC8-001-2.09, Edition 08.2016
Class 1 data
If several data points are to be transmitted to the central station (spontaneous or on request) at the same
time, the Class 1 data will be sent before the Class 2 data (priority).
With dial-up traffic, data of the Class 1 lead to a spontaneous connection setup and data transmission.
Class 2 data
If several data points are to be transmitted to the central station (spontaneous or on request) at the same
time, the Class 2 data will be sent after the Class 1 data.
With dial-up traffic, the connection setup and the data transmission takes place only upon interrogation by
the central station.
Command direction
Transmission facility from the central station to a substation
Command return information
The command return information is an additional information for the double-point information, displays the
reason for the status change (breaker tripping or switching operation in progress)
Configuration
Configuration is used in a multiple meaning:
a) engineering of the configuration of an automation unit in the engineering tool
b) physical aligning and mounting of the configured hardware
– plugging in the slot defined by the configuration (slot addressing), or
– setting the address defined by the configuration, and plugging in an arbitrary slot (adjustable address)
COT
ž
Cause of Transmission
CPU
Central Processing Unit
CTS
Clear to Send, handshake control line of an RS-232 interface
Cyclic transmission
Periodical transmission according to the scan rate of the application program
D
Data class
This assignment is specified in the standard IEC 60870-5-101/-104, and serves for the priorization of in-
formation objects for the transmission by the communication function:
ž
Class 1 data
ž
Class 2 data
Dataflow routing
Functions and methods for distribution of messages to ist targets:
ž
Automatic data flow routing
ž
Selective data flow routing
Datapoint
Analog or binary information (process data point, System data point)
Data stream
Transports a sequence of data-point related information through the telecontrol system from a source to
one or more sinks.
There are spontaneous and periodical data streams. (spontaeous data strems transport information in tel-
egrams)
Datentransporter and system message router
System-internal distribution point for application data and system data messages from and to the single
systemfunctions resp. application; application data is distributed by means of routing, system data by
means of target addressing to the data sinks
DCD
Data Carrier Detect; control line of a RS-232 interface for the evaluation of the receive signal level
Содержание SICAM CMIC
Страница 8: ...Preface 8 SICAM RTUs User Manual SICAM CMIC DC8 001 2 09 Edition 08 2016 ...
Страница 10: ...Open Source Software Used in SICAM CMIC 10 SICAM RTUs User Manual SICAM CMIC DC8 001 2 09 Edition 08 2016 ...
Страница 20: ...Table of Contents 20 SICAM RTUs User Manual SICAM CMIC DC8 001 2 09 Edition 08 2016 Glossary 405 ...
Страница 46: ...Installation 46 SICAM RTUs User Manual SICAM CMIC DC8 001 2 09 Edition 08 2016 ...
Страница 62: ...Interfaces and Circuitry 62 SICAM RTUs User Manual SICAM CMIC DC8 001 2 09 Edition 08 2016 ...
Страница 102: ...Preparing the Engineering 102 SICAM RTUs User Manual SICAM CMIC DC8 001 2 09 Edition 08 2016 ...
Страница 130: ...Engineering via SICAM TOOLBOX II 130 SICAM RTUs User Manual SICAM CMIC DC8 001 2 09 Edition 08 2016 ...
Страница 334: ...Error Handling 334 SICAM RTUs User Manual SICAM CMIC DC8 001 2 09 Edition 08 2016 ...
Страница 386: ...Set Up Dial Up Connection via PPP 386 SICAM RTUs User Manual SICAM CMIC DC8 001 2 09 Edition 08 2016 ...
Страница 394: ...Install Security Certificate 394 SICAM RTUs User Manual SICAM CMIC DC8 001 2 09 Edition 08 2016 ...
Страница 404: ...Use Cases 404 SICAM RTUs User Manual SICAM CMIC DC8 001 2 09 Edition 08 2016 ...
Страница 414: ...Glossary 414 SICAM RTUs User Manual SICAM CMIC DC8 001 2 09 Edition 08 2016 X Z ...