The following types of protection are possible:

• nA

ATEX classification: II 3G Ex nA IIC T4 Gc
Certificate no.: KEMA 07ATEX0145 X
The products meet the requirements of the following standards:

– EN 60079-15 (Explosive atmospheres - Part 15: Equipment protection by type of 

protection "n")

– EN 60079-0 (Explosive atmospheres - Part 0: Equipment - General requirements)

• ec 

ATEX classification: II 3 G Ex ec IIC T4 Gc
Certificate no.: DEKRA 18ATEX0025X
The products meet the requirements of the following standards:

– EN 60079-7 (Explosive atmospheres - Part 7: Equipment protection through increased 

safety "e")

– EN 60079-0 (Explosive atmospheres - Part 0: Equipment - General requirements)

You will find the current versions of the standards in the currently valid ATEX certificates.

IECEx

The SIMATIC NET products described in these operating instructions meet the requirements of 
explosion protection according to IECEx.

Note
Type of protection of the device

The devices are approved for various types of protection. You can find the type of protection of 
your device and the IECEx certificate number on the nameplate.

Permitted types of protection

The following types of protection are possible:

• nA

IECEx classification: Ex nA IIC T4 Gc
Certificate no.: DEK 14.0025X
The products meet the requirements of the following standards:

– IEC 60079-15 (Explosive atmospheres - Part 15: Equipment protection by type of 

protection "n")

– IEC 60079-0 (Explosive atmospheres - Part 0: Equipment - General requirements)

• ec

IECEx classification: Ex ec IIC T4 Gc
Certificate no.: DEK 18.0017X
The products meet the requirements of the following standards:

– IEC 60079-7 (Explosive atmospheres - Part 7: Equipment protection through increased 

safety "e")

– IEC 60079-0 (Explosive atmospheres - Part 0: Equipment - General requirements)

Approvals

SCALANCE XP-200
Operating Instructions, 03/2021, C79000-G8976-C428-08

91

Содержание SCALANCE XP208EEC

Страница 1: ...rating Instructions 03 2021 C79000 G8976 C428 08 Introduction 1 Safety notices 2 Recommendations on network security 3 Description of the device 4 Installation 5 Connecting up 6 Upkeep and maintenance 7 Technical specifications 8 Dimension drawings 9 Approvals A ...

Страница 2: ...re those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufacturers are used ...

Страница 3: ... 29 4 3 5 LEDs DM1 and DM2 29 4 3 6 LEDs L1 and L2 30 4 3 7 Port LEDs 31 4 4 RESET button 33 4 5 SELECT SET button 35 4 6 C PLUG 37 4 6 1 Function of the C PLUG 37 4 6 2 Replacing the C PLUG 38 4 7 Power over Ethernet PoE 41 5 Installation 45 5 1 Safety notices for installation 45 5 2 Types of installation 48 5 3 Wall mounting 49 5 4 Wall mounting 50 5 5 Rack mounting 51 6 Connecting up 53 6 1 Saf...

Страница 4: ...echnical specifications SCALANCE XP208 and SCALANCE XP208EEC 75 8 2 Technical specifications of the SCALANCE XP208PoE EEC 77 8 3 Technical specifications SCALANCE XP216 and SCALANCE XP216EEC 79 8 4 Technical specifications of the SCALANCE XP216PoE EEC 81 8 5 Cable lengths 83 8 6 Switching properties 84 9 Dimension drawings 85 A Approvals 89 Index 95 Table of contents SCALANCE XP 200 4 Operating In...

Страница 5: ...of some devices refer to the section Product overview Page 17 Designations used Classification Description Terms used Product line The product line includes all devices and variants of all product groups If information applies to all product groups within the product line the term SCALANCE X 200 is used SCALANCE X 200 Product group If information applies to all devices and variants of a product gr...

Страница 6: ... system manuals here On the data medium that ships with some products Product CD product DVD SIMATIC NET Manual Collection On the Internet pages of Siemens Industry Online Support Industrial Ethernet PROFINET Industrial Ethernet System Manual https support industry siemens com cs ww en view 27069465 Industrial Ethernet PROFINET Passive Network Components System Manual https support industry siemen...

Страница 7: ...com industrialsecurity https www siemens com industrialsecurity Siemens products and solutions undergo continuous development to make them more secure Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used Use of product versions that are no longer supported and failure to apply the latest updates may increase custom...

Страница 8: ...fied by the registered trademark sign are registered trademarks of Siemens AG SIMATIC NET SCALANCE C PLUG OLM Electrostatic discharge NOTICE Electrostatic sensitive devices ESD Electronic modules contain electrostatic sensitive components These components can easily be destroyed if handled incorrectly Note the following instructions to avoid damage Touch electronic modules only when you absolutely...

Страница 9: ...al safety notices relating to protection against explosion WARNING EXPLOSION HAZARD Do not open the device There are no serviceable parts inside of the device WARNING EXPLOSION HAZARD Do not open the device when the supply voltage is turned on Safety notices when using the device according to Hazardous Locations HazLoc If you use the device under HazLoc conditions you must also keep to the followi...

Страница 10: ...Safety notices SCALANCE XP 200 10 Operating Instructions 03 2021 C79000 G8976 C428 08 ...

Страница 11: ...ctionality to encrypt and authenticate the communication No product liability will be accepted for operation in a non secure infrastructure Terminate management connections correctly WBM Telnet SSH etc Physical access Restrict physical access to the device to qualified personnel because the plug in data medium can contain sensitive data Lock unused physical interfaces on the device Unused interfac...

Страница 12: ...e contains a pre installed certificate with key Replace this certificate with a self made certificate with key We recommend that you use a certificate signed either by a reliable external or by an internal certification authority You can install the certificate via the WBM System Load and Save Use the certification authority including key revocation and management to sign the certificates Make sur...

Страница 13: ...es If no unrestricted access is necessary restrict access with SNMP Use the authentication and encryption mechanisms of SNMPv3 Use secure protocols when access to the device is not prevented by physical protection measures If you require non secure protocols and services operate the device only within a protected network area Restrict the services and protocols available to the outside to a minimu...

Страница 14: ...ols local access via a local network The following is a list of all available protocols and their ports through which the device can be accessed Protocol Protocol Port number Default port sta tus Configurable port Authentication Encryption DHCPv4 Server UDP 67 Closed No No DHCPv4 Client UDP 68 Open No No Discard TCP 9 Open filtered No No Echo IP UPD TCP 9 Open No No EtherNet IP TCP 44818 UDP 2222 ...

Страница 15: ...1813 Closed Yes Yes SMTP TCP 25 TCP 465 Closed Yes Yes SNMP UDP 161 Open Yes Yes when con figured SSH TCP 22 Open Yes Yes Syslog UPD 514 TCP 6514 Closed Yes Yes TELNET TCP 23 Open Yes No TFTP UDP 69 Open No No 1 Port number can be configured via the WBM Recommendations on network security SCALANCE XP 200 Operating Instructions 03 2021 C79000 G8976 C428 08 15 ...

Страница 16: ...Recommendations on network security SCALANCE XP 200 16 Operating Instructions 03 2021 C79000 G8976 C428 08 ...

Страница 17: ...SCALANCE XP216 12 x 10 100 Mbps and 4 x 10 100 1000 Mbps M12 connector technology electri cal 6GK5 216 0HA00 2TS6 6GK5 216 0HA00 2AS6 SCALANCE XP216EEC 12 x 10 100 Mbps and 4 x 10 100 1000 Mbps M12 connector technology electri cal varnished circuit board 6GK5 216 0HA00 2ES6 SCALANCE XP216PoE EEC 12 x 10 100 Mbps und 4 x 10 100 1000 Mbps M12 connector tech nology electrical varnished circuit board ...

Страница 18: ...ctrical connectors PoE XP2 Property Description EEC Enhanced Environmental Conditions PoE Power over Ethernet Unpacking and checking WARNING Do not use any parts that show evidence of damage If you use damaged parts there is no guarantee that the device will function according to the specification If you use damaged parts this can lead to the following problems Injury to persons Loss of the approv...

Страница 19: ...00 0AQ00 M12 data plug in connector Component Description Article number IE FC M12 PLUG PRO 2x2 M12 data plug in con nector for IE FC TP ca bles 2x2 IP65 67 D co ded axial cable outlet 1 connector per package 6GK1 901 0DB20 6AA0 8 connectors per package 6GK1 901 0DB20 6AA8 IE FC M12 PLUG PRO 4x2 M12 data plug in con nector for IE FC TP ca bles 4x2 IP65 67 X co ded axial cable outlet 1 connector pe...

Страница 20: ...CAT 5 Sold by the meter 6XV1 870 2B IE FC TP TRAILING CABLE 2X2 PROFINET type C Highly flexible bus cable TP instal lation cable for connection to FC OUTLET RJ45 for use in drag chains 4 wire shielded CAT 5 Sold by the meter 6XV1 840 3AH10 IE TP TORSION CABLE 2X2 PROFINET type C Highly flexible bus cable TP instal lation cable for use in highly flexible applications torsion 4 wire Sold by the mete...

Страница 21: ...power supply input 120 to 230 VAC output 24 VDC 5A IP67 6EP1 333 7CA00 Stabilized power supply input 120 to 230 VAC output 24 VDC 8A IP67 6EP1 334 7CA00 Available in different lengths Energy cable Component Description Article number Energy cable 2 x 0 75 Energy cable for connection of signaling contact and power supply 24 VDC stran ded wire 2 x 0 75 mm2 capable of trailing not assembled Sold by t...

Страница 22: ...00 mm ready for installation pack of 1 6ES7 194 4GA60 0AA0 Length 2000 mm pack of 1 6ES7 194 4GA20 0AA0 Rack wide Length 500 mm ready for installation pack of 1 6ES7 194 4GB00 0AA0 Length 1000 mm ready for installation pack of 1 6ES7 194 4GB60 0AA0 Length 2000 mm pack of 1 6ES7 194 4GB20 0AA0 Rack compact narrow Length 500 mm ready for installation pack of 1 6ES7 194 4GC70 0AA0 Length 1000 mm read...

Страница 23: ...nt Description Article number M12 protective caps Protective caps to protect unused M12 sockets and plugs Pack of 8 for sockets and 2 for plugs 6GK5 980 2FA00 0AA0 Description of the device 4 1 Product overview SCALANCE XP 200 Operating Instructions 03 2021 C79000 G8976 C428 08 23 ...

Страница 24: ...exagonal nuts Keyhole hang up mechanism Ethernet ports for Fast Ethernet Grounding point Power supply redundant Signaling contact Securing point for covering the serial interface Serial interface SELECT SET button LED display Cover for C PLUG slot RESET button Description of the device 4 2 Device views SCALANCE XP 200 24 Operating Instructions 03 2021 C79000 G8976 C428 08 ...

Страница 25: ... ports for Fast Ethernet P1 P4 b Ethernet ports for Fast Ethernet and PoE P5 P8 Grounding point Power supply redundant Signaling contact Securing point for covering the serial interface Serial interface SELECT SET button LED display Cover for C PLUG slot RESET button Description of the device 4 2 Device views SCALANCE XP 200 Operating Instructions 03 2021 C79000 G8976 C428 08 25 ...

Страница 26: ...t ports for Fast Ethernet P1 P8 P9 P11 P13 and P15 b Ethernet ports for Gigabit Ethernet P10 P12 P14 and P16 Grounding point Power supply redundant Signaling contact Securing point for covering the serial interface Serial interface SELECT SET button LED display Cover for C PLUG slot RESET button Description of the device 4 2 Device views SCALANCE XP 200 26 Operating Instructions 03 2021 C79000 G89...

Страница 27: ...Gigabit Ethernet P10 und P12 c Ethernet ports for Fast Ethernet and PoE P5 P8 P13 and P15 d Ethernet ports for Gigabit Ethernet and PoE P14 and P16 Grounding point Power supply redundant Signaling contact Securing point for covering the serial interface Serial interface SELECT SET button LED display Cover for C PLUG slot RESET button Description of the device 4 2 Device views SCALANCE XP 200 Opera...

Страница 28: ... port LEDs depends on the device 4 3 2 RM LED The RM LED indicates whether or not the device is a redundancy manager and whether or not the ring is operating free of error LED color LED status Meaning Off The device is not a redundancy manager Green On The device is a redundancy manager The ring is working without problems monitoring is activated Green Flashing The device is a redundancy manager A...

Страница 29: ... the firmware Meaning during operation LED color LED status Meaning during operation Off The device is operating free of errors The signaling contact is closed Red On The device has detected a problem The signaling contact has opened 4 3 5 LEDs DM1 and DM2 The DM1 and DM2 LEDs indicate which display mode is set There are 5 display modes A B C D and E Display mode A is the default mode Depending on...

Страница 30: ...ower supply at connectors L1 and L2 The meaning of the L1 and L2 LEDs depends on the set display mode see section LEDs DM1 and DM2 Page 29 Meaning in display modes A B C and E In display modes A B C and E from the L1 and L2 LEDs you can see whether the power supply is higher or lower than a certain voltage limit Table 4 1 Power supply with devices with 24 VDC L1 L2 LEDs L1 L2 connector LED color L...

Страница 31: ...The meaning of the Port LEDs depends on the set display mode see section LEDs DM1 and DM2 Page 29 Meaning in display mode A In display mode A the port LEDs indicate whether a valid link exists LED color LED status Meaning Off No valid link to the port for example station turned off or cable not connected Green On Link exists and port in normal status In this status the port can receive and send da...

Страница 32: ...status Meaning Off Port operating in half duplex mode Green On Port operating in full duplex mode Meaning in display mode D In display mode D the port LEDs indicate whether the port is monitored LED color LED status Meaning Off Port is not monitored If no link was established at the port the signaling contact does not indicate an error Green On Port is monitored If no link was established at the p...

Страница 33: ...the RESET button for example on the SCALANCE XP208 Resetting the device to factory defaults NOTICE Previous settings If you reset all the changes you have made will be overwritten by factory defaults NOTICE Inadvertent reset An inadvertent reset can cause disturbances and failures in theconfigured network with further consequences Description of the device 4 4 RESET button SCALANCE XP 200 Operatin...

Страница 34: ... Remove the cover 3 Hold down the RESET button for 12 seconds Note The RESET button is a long stroke button with a pressure point Press the button until you feel the pressure point After 9 seconds the DM1 and DM2 LEDs start to flash for 3 seconds At the same time the port LEDs go on one after the other After you have held down the button for 12 seconds the factory defaults are restored If you rele...

Страница 35: ...tting the display mode To set the required display mode press the SELECT SET button For more detailed information on the display modes refer to the section LEDs DM1 and DM2 Page 29 Defining the fault mask Using the fault mask you specify an individual good status for the connected ports and the power supply Deviations from this status are displayed as errors faults You configure the monitoring of ...

Страница 36: ...n the SELECT SET button for 5 seconds After 2 seconds the DM1 and DM2 LEDs start to flash for 3 seconds At the same time the port LEDs go on one after the other After you have held down the button for 5 seconds the current settings are stored as the good status If you release the button before the 5 seconds have elapsed the previous fault mask will be retained Description of the device 4 5 SELECT ...

Страница 37: ...es for the device Without C PLUG The device stores the configuration in internal memory This mode is active if no C PLUG is inserted With unwritten C PLUG If an unwritten C PLUG factory status or deleted with Clean function is used the local configuration already existing on the device is automatically stored on the inserted C PLUG during startup This mode is active as soon as an unwritten C PLUG ...

Страница 38: ...o reformat the C PLUG 4 6 2 Replacing the C PLUG Position of the C PLUG NOTICE Loss of water and dust protection If the cover is not mounted correctly the device is not water and dust proof NOTICE Loss of the railway approval If you use an unvarnished C PLUG the device does not comply with the railway standard EN50155 NOTICE Do not remove or insert a C PLUG during operation The C PLUG may only be ...

Страница 39: ...ing torque 8 Nm to ensure that the device is closed and water and dust proof Note Loss of the configuration The RESET Page 33 button is located directly beside the slot for the C PLUG The button cannot be used to remove the C PLUG If you hold down the RESET button you reset all settings of the device to the factory defaults Remove the C PLUG with a screwdriver Description of the device 4 6 C PLUG ...

Страница 40: ...s a protruding ridge on the long side B The slot has a groove at this position Insert the C PLUG correctly oriented into the slot 5 Close the cover tightening torque 8 Nm to ensure that the device is closed and water and dust proof Description of the device 4 6 C PLUG SCALANCE XP 200 40 Operating Instructions 03 2021 C79000 G8976 C428 08 ...

Страница 41: ...Power consumer 37 0 57 0 V 42 5 57 0 V PoE variants The PoE variants of SCALANCE XP 200 are power sources and have 4 or 8 PoE ports Via the PoE ports devices capable of PoE can be supplied with power via the Ethernet cable Note You can also use the PoE ports without the PoE function A voltage is applied only after the device has detected an end device capable of PoE at the port With devices not ca...

Страница 42: ...er Sample configuration for PoE ports on SCALANCE XP 200 The following configuration graphics show as examples how power supply via PoE might look with SCALANCE XP 200 In all examples 120 W is available through the SCALANCE XR216PoE EEC These 120 W are used differently in the examples In example 1 the 120 W are used to operate 4 power consumers which each consume approx 25 5 W In example 2 the 120...

Страница 43: ... P13 P16 Configuration How you activate and configure PoE is described in the configuration manuals see section Introduction section Documentation on configuration Power transfer and pin assignment The voltage is transferred on the data wires 1 2 3 and 4 of the Ethernet cable D coded ports 3 Pin number Assignment Pin 1 negative power supply Pin 2 positive power supply Description of the device 4 7...

Страница 44: ...number Assignment Pin 1 negative power supply Pin 2 negative power supply Pin 3 positive power supply Pin 4 positive power supply Pin 5 Pin 6 Pin 7 Pin 8 Description of the device 4 7 Power over Ethernet PoE SCALANCE XP 200 44 Operating Instructions 03 2021 C79000 G8976 C428 08 ...

Страница 45: ...han 40 WARNING If the device is installed in a cabinet the inner temperature of the cabinet corresponds to the ambient temperature of the device Safety notices on use in hazardous areas General safety notices relating to protection against explosion WARNING EXPLOSION HAZARD Replacing components may impair suitability for Class 1 Division 2 or Zone 2 WARNING The device may only be operated in an en...

Страница 46: ...able enclosure that provides a degree of protection not less than IP54 in accordance with EN IEC 60079 15 Safety notices when using according to FM If you use the device under FM conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion WARNING Wall mounting outside of the control cabinet or housing does not fulfill the...

Страница 47: ...device and can lead to premature aging of the IE switch and its cabling Provide suitable shade to protect the IE switch against direct sunlight Note During installation and operation keep to the installation guidelines and safety notices described in this document and in the system manuals Industrial Ethernet PROFINET Industrial Ethernet and Industrial Ethernet PROFINET passive network components ...

Страница 48: ...pes of installation The SCALANCE XP 200 can be installed in the following ways Wall mounting Wall mounting Rack mounting Installation 5 2 Types of installation SCALANCE XP 200 48 Operating Instructions 03 2021 C79000 G8976 C428 08 ...

Страница 49: ...repare the drill holes for wall mounting For the precise dimensions refer to the section Dimension drawings 2 Screw the device to the wall using the keyhole hang up mechanisms 3 Fit the connectors for the power supply see the section Power supply 4 Fit the connectors for the signaling contact refer to the section Signaling contacts Installation 5 3 Wall mounting SCALANCE XP 200 Operating Instructi...

Страница 50: ...ace the hexagon nuts in the corresponding cutouts The nuts cannot be turned in the cutouts 4 Push the screws through the drill holes and screw them to the nuts 5 Fit the connectors for the power supply see the section Power supply Page 59 6 Fit the connectors for the signaling contact refer to the section Signaling contact Page 64 Removal To remove the device from the wall follow the steps below 1...

Страница 51: ...erview Page 17 2 Fit the connectors for the power supply see the section Power supply Page 59 3 Fit the connectors for the signaling contact refer to the section Signaling contact Page 64 Note Grounding The device is not grounded via the rack by the keyhole hang up mechanisms If necessary connect a separate ground Removal To remove the device from a rack follow the steps below 1 Disconnect all con...

Страница 52: ...Installation 5 5 Rack mounting SCALANCE XP 200 52 Operating Instructions 03 2021 C79000 G8976 C428 08 ...

Страница 53: ...h Safety Extra Low Voltage SELV by a Limited Power Source LPS This means that only SELV LPS complying with IEC 60950 1 EN 60950 1 VDE 0805 1 must be connected to the power supply terminals or the power supply unit for the equipment power supply must comply with NEC Class 2 as described by the National Electrical Code r ANSI NFPA 70 If the equipment is connected to a redundant power supply two sepa...

Страница 54: ...eed to fuse the supply cable if you only use power sources with a limited power source LPS or power sources according to NEC Class 2 for the power supply of the devices Note Close unused sockets Close all unused M12 sockets with protective caps tightening torque at least 0 4 Nm to achieve the specified type of protection Safety notices on use in hazardous areas General safety notices relating to p...

Страница 55: ...ltage WARNING Provisions shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 119 V WARNING EXPLOSION HAZARD Do not press the SELECT SET button when there is an explosive atmosphere WARNING Safety notice for connecting with a LAN ID Local Area Network A LAN or LAN segment with all the interconnected devices should be contained completely in a single...

Страница 56: ...ustrial Ethernet at 10 100 Mbps the device has the following M12 interfaces D coded 4 pin female 3 Pin number Assignment 1 TD 2 RD 3 TD 4 RD Gigabit Ethernet For connection to Industrial Ethernet at 10 100 1000 Mbps the device has the following M12 interfaces X coded 8 pin female 3 Connecting up 6 2 Industrial Ethernet SCALANCE XP 200 56 Operating Instructions 03 2021 C79000 G8976 C428 08 ...

Страница 57: ...ange the angled M12 plug as follows IE FC M12 PLUG PRO The IE FC M12 Plug PRO has a high degree of protection IP65 67 and is suitable for connecting to Industrial Ethernet see the section Product overview Page 17 Ring ports When shipped the ring ports are marked by a label The labels are only clipped on and you can remove them if necessary Connecting up 6 2 Industrial Ethernet SCALANCE XP 200 Oper...

Страница 58: ... means the automatic detection negotiation of the transmission rate and the operating mode of ports at the opposite end This makes it possible to configure different devices automatically Two components connected to a link segment can exchange information about the transfer and can adapt their settings to each other The mode with the highest possible speed is set Note If a port is set permanently ...

Страница 59: ... 200 to electromagnetic interference was the surge immunity test according to EN61000 4 5 This test requires overvoltage protection for the power supply lines A suitable device is for example the Dehn Blitzductor BVT AVD 24 article number 918 422 or a comparable protective element Manufacturer DEHN SOEHNE GmbH Co KG Hans Dehn Str 1 Postfach 1640 D92306 Neumarkt Germany Operate the SCALANCE XP 200 ...

Страница 60: ...efore you insert or remove the plug of the power supply 1 Connect the plug and socket Make sure that they lock in place correctly 2 Tighten the knurled screw torque 1 Nm M12 Power T Tap To connect several devices to a power supply so that they are cascading you can use an M12 Power T Tap see the section Product overview Page 17 The M12 Power T Tap has two M12 sockets and one M12 plug Note The M12 ...

Страница 61: ...ased for ambient temperatures from 25 C to 85 C In the specified temperature range you can load the M12 Power T Tap with up to 2 A Connecting up 6 3 24 VDC power supply SCALANCE XP 200 Operating Instructions 03 2021 C79000 G8976 C428 08 61 ...

Страница 62: ...he power supply to the power consumers is ensured see the section Power over Ethernet PoE Page 41 For the cable supplying the power supply use a cable with a length of max 3 m To connect the power supply use a copper cable of category 18 AWG or a cable with a cross section 0 75 mm see e g the section Product overview Page 17 To connect to the power supply the device has two M12 interfaces A coded ...

Страница 63: ...onnecting the power supply NOTICE Turn off the power supply before you insert or remove the plug of the power supply 1 Connect the plug and socket Make sure that they lock in place correctly 2 Tighten the knurled screw torque 1 Nm Note Restriction of the power consumers To supply Poe consumers of type 2 according to the standard the power supply must provide an output voltage in the range 52 57 VD...

Страница 64: ...t the signaling contact use a copper cable of category 24 AWG or a cable with a cross section of 0 25 mm2 see for example section Product overview Page 17 NOTICE Damage due to voltage being too high You can load the signaling contact with the operating voltage of the device and a maximum of 100 mA Higher voltages or currents can damage the device Position and assignment 8 7 Figure 6 3 Position of ...

Страница 65: ...ect a communications node to an unmonitored port or disconnect it this does not cause an error message The signaling contact remains open until one of the following events occurs The problem is eliminated The current status is entered in the fault mask as the new desired status Connecting the signaling contact 1 Connect the plug and socket Make sure that they lock in place correctly 2 Tighten the ...

Страница 66: ...ps the cover for the serial interface is secured to the housing see Device views Page 24 Position and assignment 2162 5 7 0 Figure 6 4 Position and pin assignment of the serial interface for example on the SCALANCE XP208 Pin number Assignment 1 Tx Transmit Data 2 Rx Receive Data 3 internal use only do not connect 4 M Signal Ground 5 internal use only do not connect Assignment of the terminal block...

Страница 67: ... Signal Ground 5 M Signal Ground 6 7 8 9 Connecting the serial interface 1 Connect the plug and socket Make sure that they lock in place correctly 2 Tighten the knurled screw torque 1 Nm Connecting up 6 6 Serial interface SCALANCE XP 200 Operating Instructions 03 2021 C79000 G8976 C428 08 67 ...

Страница 68: ... property from too high contact voltages Apart from the protective ground there is functional grounding in the cabinet According to EN60204 1 DIN VDE 0113 T1 operational electrical circuits must be grounded The chassis 0 V is grounded at one defined point Here once again the grounding is implemented with the lowest leakage resistance to ground in the vicinity of the power feed in With automation c...

Страница 69: ...washer Follow the steps below to connect the functional ground 1 Put the grounding terminal and the bolt together as shown in the drawing 2 Screw in the bolt with a maximum tightening torque of 1 5 Nm Connecting up 6 7 Functional ground SCALANCE XP 200 Operating Instructions 03 2021 C79000 G8976 C428 08 69 ...

Страница 70: ...Connecting up 6 7 Functional ground SCALANCE XP 200 70 Operating Instructions 03 2021 C79000 G8976 C428 08 ...

Страница 71: ...vice 2 Press the SELECT SET button and reconnect the power supply to the device while holding down the button 3 Hold down the button until the red fault LED F starts to flash 4 Release the button as long as the red error LED is still flashing This time only lasts a few seconds The bootloader of the device waits in this status for a new firmware file that you can download by TFTP 5 Connect a PC to ...

Страница 72: ...n disabled with the configuration it is only disabled on completion of the startup phase When pressing the button observe the information in the section RESET button Page 33 To reset the device to the factory defaults during the startup phase follow the steps below 1 Turn off the power to the device 2 Loosen the screws of the cover 3 Remove the cover 4 Press the RESET button and reconnect the powe...

Страница 73: ...Note Loss of the IP address When the settings are reset to the default settings of a PROFINET IO profile the IP address is also lost The device can then only be addressed via the serial interface SINEC PNI or via DHCP Restore Factory Defaults Resets the selected device to factory settings 3 Confirm the selection with OK During configuration You will find detailed information on resetting the devic...

Страница 74: ...Upkeep and maintenance 7 2 Restoring the factory settings SCALANCE XP 200 74 Operating Instructions 03 2021 C79000 G8976 C428 08 ...

Страница 75: ... DC Safe Extra Low Volt age 1 Design M12 socket 4 pin Cable cross section 0 25 mm2 24 AWG Property Implemented redundantly Current consumption at 24 VDC 200 mA Effective power loss at 24 VDC 4 8 W Fusing 5 A at least 60 V Or power supply with LPS or NEC class 2 Permitted ambient conditions Ambient temperature During operation up to 2000 m 40 C to 70 C 2 During storage 40 to 70 During transportatio...

Страница 76: ...7 years 1 The SCALANCE XP208EEC with EN 50155 support the voltage range 16 8 30 VDC These values are not valid for other approvals 2 EEC variants with EN 50155 support 85 C for 10 minutes Technical specifications 8 1 Technical specifications SCALANCE XP208 and SCALANCE XP208EEC SCALANCE XP 200 76 Operating Instructions 03 2021 C79000 G8976 C428 08 ...

Страница 77: ... mm2 18 AWG Property Implemented redundantly Current consumption At 54 VDC without PoE load 110 mA At 54 VDC with max PoE load 2500 mA Effective power loss At 54 VDC 6 W At 54 VDC in PoE operation 9 W Fusing 5 A at least 60 V PoE power per device At 54 VDC 120 W Permitted ambient conditions Ambient temperature During operation up to 2000 m 40 C to 70 C 1 During storage 40 to 70 During transportati...

Страница 78: ...re MTBF MTBF EN IEC 61709 40 C 49 years 1 EEC variants with EN 50155 support 85 C for 10 minutes Technical specifications 8 2 Technical specifications of the SCALANCE XP208PoE EEC SCALANCE XP 200 78 Operating Instructions 03 2021 C79000 G8976 C428 08 ...

Страница 79: ... age 1 Design M12 socket 4 pin Cable cross section 0 25 mm2 24 AWG Property Implemented redundantly Current consumption at 24 VDC 400 mA Effective power loss at 24 VDC 9 6 W Fusing 5 A at least 60 V Or power supply with LPS or NEC class 2 Permitted ambient conditions Ambient temperature During operation up to 2000 m 40 C to 70 C 2 During storage 40 to 70 During transportation 40 to 70 Relative hum...

Страница 80: ...9 years 1 The SCALANCE XP216EEC with EN 50155 support the voltage range 16 8 30 VDC These values are not valid for other approvals 2 EEC variants with EN 50155 support 85 C for 10 minutes Technical specifications 8 3 Technical specifications SCALANCE XP216 and SCALANCE XP216EEC SCALANCE XP 200 80 Operating Instructions 03 2021 C79000 G8976 C428 08 ...

Страница 81: ...ocket 4 pin Cable cross section 0 75 mm2 18 AWG Property Implemented redundantly Current consumption At 54 VDC without PoE load 180 mA At 54 VDC with max PoE load 2500 mA Effective power loss At 54 VDC 10 W At 54 VDC in PoE operation 13 W Fusing 5 A at least 60 V PoE power per device At 54 VDC 120 W Permitted ambient conditions Ambient temperature During operation up to 2000 m 40 C to 70 C 1 Durin...

Страница 82: ...re MTBF MTBF EN IEC 61709 40 C 29 years 1 EEC variants with EN 50155 support 85 C for 10 minutes Technical specifications 8 4 Technical specifications of the SCALANCE XP216PoE EEC SCALANCE XP 200 82 Operating Instructions 03 2021 C79000 G8976 C428 08 ...

Страница 83: ...55 m IE FC TP Marine Trailing Flexible cable with IE FC Outlet RJ 45 10 m TP cord 0 to 75 m 10 m TP cord IE FC TP Marine Trailing Flexible cable with IE FC RJ 45 Plug 180 0 to 85 m IE FC TP standard cable with IE FC Outlet RJ 45 10 m TP cord 0 to 90 m 10 m TP cord IE FC TP standard cable with IE FC RJ 45 Plug 180 0 to 100 m Technical specifications 8 5 Cable lengths SCALANCE XP 200 Operating Instr...

Страница 84: ...ng technique Store and forward Latency 10 microseconds Full wire speed switching Frame length bytes Number of frames per second at 100 Mbps 64 148810 128 84459 256 45290 512 23496 1024 11973 1280 9615 1518 8127 Note The number of SCALANCE XP 200 modules connected in a line influences the frame delay When a frame passes through the IE switch this is delayed by the store and forward function of the ...

Страница 85: ...n drawings 9 Note Dimensions are specified in mm Front view of the SCALANCE XP208 Figure 9 1 Width height and dimensions for wall mounting SCALANCE XP 200 Operating Instructions 03 2021 C79000 G8976 C428 08 85 ...

Страница 86: ...Front view of the SCALANCE XP216 Figure 9 2 Width height and dimensions for wall mounting Dimension drawings SCALANCE XP 200 86 Operating Instructions 03 2021 C79000 G8976 C428 08 ...

Страница 87: ...Side view of the SCALANCE XP 200 Figure 9 3 Depth Dimension drawings SCALANCE XP 200 Operating Instructions 03 2021 C79000 G8976 C428 08 87 ...

Страница 88: ...Dimension drawings SCALANCE XP 200 88 Operating Instructions 03 2021 C79000 G8976 C428 08 ...

Страница 89: ... conformity The SIMATIC NET products described in these operating instructions meet the requirements and safety objectives of the following EC directives and comply with the harmonized European standards EN which are published in the official documentation of the European Union and here 2014 34 EU ATEX explosion protection directive Directive of the European Parliament and the Council of 26 Februa...

Страница 90: ...ubassemblies modules in a Zone 2 Hazardous Area You will find this document on the data medium that ships with some devices on the Internet pages of Siemens Industry Online Support https support industry siemens com cs ww en view 78381013 Enter the document identification number C234 as the search term The SIMATIC NET products described in these operating instructions meet the requirements of the ...

Страница 91: ...ctions meet the requirements of explosion protection according to IECEx Note Type of protection of the device The devices are approved for various types of protection You can find the type of protection of your device and the IECEx certificate number on the nameplate Permitted types of protection The following types of protection are possible nA IECEx classification Ex nA IIC T4 Gc Certificate no ...

Страница 92: ...HS The SIMATIC NET products described in these operating instructions meet the requirements of the EC directive 2011 65 EC for the restriction of the use of certain hazardous substances in electrical and electronic equipment Applied standard EN 50581 FM The product meets the requirements of the standards Factory Mutual Approval Standard Class Number 3611 FM Hazardous Classified Location Electrical...

Страница 93: ... railway stock a stabilized power supply must be used to comply with EN50155 Note for Australia RCM The product meets the requirements of the RCM standard Applied standards AS NZS CISPR11 Industrial scientific and medical equipment Radio frequency disturbance characteristics Limits and methods of measurement EN 61000 6 4 Electromagnetic compatibility EMC Part 6 4 Generic standards Emission standar...

Страница 94: ...System Manual https support industry siemens com cs ww en view 27069465 Industrial Ethernet PROFINET Passive Network Components System Manual https support industry siemens com cs ww en view 84922825 EMC Installation Guidelines configuration manual https support industry siemens com cs ww en view 60612658 WARNING Personal injury and property damage can occur The installation of expansions that are...

Страница 95: ...Replacing 38 D Data cable 20 Data line 20 Defining the fault mask 35 Dimensions 75 77 79 81 Display mode 29 35 E E1 93 Electrical data 75 77 79 81 Energy cable 21 Environmental conditions 75 77 79 81 ESD directives 8 F Factory defaults 33 72 Factory setting 33 72 Fast Ethernet Connecting up 56 Overview 24 25 26 27 Fault mask 35 Fault error status 29 Firmware 29 Functional ground Connecting up 68 G...

Страница 96: ...26 27 Power supply unit 21 Power T tap 22 60 Protective cap 23 Protective caps 19 R Rack 51 Reset device 33 72 Reset to Factory Defaults 34 72 S S7 300 50 Safety notices 54 for installation 45 general 9 Use in hazardous areas 9 45 53 when connecting up 53 SELECT SET button 30 71 Serial interface Connecting up 66 Cover 24 25 26 27 66 Overview 24 25 26 27 Signaling contact 29 Connecting up 64 Overvi...

Отзывы: