6.6
Serial interface
Information on the serial interface
• To connect the serial interface, the device has an M12 interface: A-coded, 5-pin, female.
• Via the serial interface, you can access the CLI of the device directly via an RS-232 connection
(115200 8N1) without assigning an IP address.
• Access to the device is also possible independent of the Ethernet ports.
• To connect the serial interface to the PC, you require a cable with an M12 plug and 9-pin D-
sub female connector. You can order the connecting cable for the serial interface as an
accessory.
• When it ships, the cover for the serial interface is secured to the housing see "Device views
(Page 24)".
Position and assignment
&2162/(
5[
7[
0
Figure 6-4
Position and pin assignment of the serial interface, for example on the SCALANCE XP208
Pin number
Assignment
1
Tx (Transmit Data)
2
Rx (Receive Data)
3
internal use only (do not connect)
4
M (Signal Ground)
5
internal use only (do not connect)
Assignment of the terminal block
The connecting cable listed in the "Accessories" section has the following pin assignment:
Pin number
Pin assignment of the M12 plug
Pin assignment of the D-sub female
connector
1
Tx (Transmit Data)
-
2
Rx (Receive Data)
Rx (Receive Data)
3
-
Tx (Transmit Data)
Connecting up
6.6 Serial interface
SCALANCE XP-200
66
Operating Instructions, 03/2021, C79000-G8976-C428-08
Содержание SCALANCE XP208EEC
Страница 10: ...Safety notices SCALANCE XP 200 10 Operating Instructions 03 2021 C79000 G8976 C428 08 ...
Страница 16: ...Recommendations on network security SCALANCE XP 200 16 Operating Instructions 03 2021 C79000 G8976 C428 08 ...
Страница 52: ...Installation 5 5 Rack mounting SCALANCE XP 200 52 Operating Instructions 03 2021 C79000 G8976 C428 08 ...
Страница 70: ...Connecting up 6 7 Functional ground SCALANCE XP 200 70 Operating Instructions 03 2021 C79000 G8976 C428 08 ...
Страница 88: ...Dimension drawings SCALANCE XP 200 88 Operating Instructions 03 2021 C79000 G8976 C428 08 ...