100104
Unsupported
802.11 rate
The AP cannot allow this client to associ-
ate because it does not support the
802.11 rate requested by this client.
Check the configuration on the AP to see if
the desired rate can be supported; if not,
consider replacing the AP with another model
that can support the rate.
100105
Maximum capaci-
ty reached on AP
The AP has reached maximum capacity
and cannot accommodate any more
clients.
Consider expanding capacity by installing
additional APs or balance load by relocating
APs.
100206
Invalid MAC
Address
The AP cannot authenticate this client
because its MAC address is not valid.
This condition may be indicative of a misbe-
having client. Try to locate the client device
and check its hardware and software.
100307
Client blocked
due to repeated
authentication
failures
The AP is temporarily blocking the
802.1X authentication request from this
client because the credentials provided
have been rejected by the RADIUS serv-
er too many times.
Identify the client and check its 802.1X cre-
dentials.
100308
RADIUS server
connection failure
The AP cannot authenticate this client
using 802.1X because the RADIUS serv-
er did not respond to the authentication
request. If the AP is using the internal
RADIUS server, it is recommend to
check the
related configuration as well as the in-
stalled certificate and passphrase.
If the AP is using the internal RADIUS server,
Siemens recommends checking the related
configuration as well as the installed certifi-
cate and passphrase.
If the AP is using an external RADIUS server,
check if there are any issues with the
RADIUS server and try connecting again.
100309
RADIUS server
authentication
failure
The AP cannot authenticate this client
using 802.1X, because the RADIUS
server rejected the authentication cre-
dentials (for example, password) provid-
ed by the client.
Ascertain the correct authentication creden-
tials and log in again.
100410
Integrity check
failure in en-
crypted message
The AP cannot receive data from this
client because the integrity check of the
received message (MIC) has failed. Rec-
ommend
checking the encryption setting on the
client and on the AP.
Check the encryption setting on the client
and on the AP.
100511
DHCP request
timed out
This client did not receive a response to
its DHCP request in time.
Recommend checking the status of the
DHCP server in the network.
Check the status of the DHCP server in the
network.
101012
Wrong Client
VLAN
VLAN mismatch between the AP and the
upstream device. Upstream device can
be upstream switch or RADIUS server.
Содержание SCALANCE W1750D UI
Страница 18: ...About this guide SCALANCE W1750D UI 18 Configuration Manual 02 2018 C79000 G8976 C451 02 ...
Страница 28: ...About SCALANCE W 3 3 SCALANCE W CLI SCALANCE W1750D UI 28 Configuration Manual 02 2018 C79000 G8976 C451 02 ...
Страница 108: ...IPv6 Support 10 4 Debugging Commands SCALANCE W1750D UI 108 Configuration Manual 02 2018 C79000 G8976 C451 02 ...
Страница 326: ......
Страница 356: ......
Страница 374: ......
Страница 416: ......
Страница 440: ......
Страница 450: ...Intrusion Detection 27 4 Configuring IDS SCALANCE W1750D UI 450 Configuration Manual 02 2018 C79000 G8976 C451 02 ...
Страница 470: ......
Страница 480: ......
Страница 496: ......
Страница 518: ...Hotspot Profiles 33 3 Sample Configuration SCALANCE W1750D UI 518 Configuration Manual 02 2018 C79000 G8976 C451 02 ...
Страница 528: ......
Страница 552: ......
Страница 570: ...Appendix B 3 Glossary SCALANCE W1750D UI 570 Configuration Manual 02 2018 C79000 G8976 C451 02 ...