AP-VPN Deployment Scenarios
35.4 Scenario 4 - GRE: Single Datacenter Deployment with No Redundancy
SCALANCE W1750D UI
550
Configuration Manual, 02/2018, C79000-G8976-C451-02
Configuration Steps
CLI Commands
UI Procedure
5. Create authentication servers for
user authentication. The example in the
next column assumes 802.1X SSID.
(scalance)(config)# wlan auth-server server1
(scalance)(Auth Server "server1")# ip
10.2.2.1
(scalance)(Auth Server "server1")# port 1812
(scalance)(Auth Server "server1")# acctport
1813
(scalance)(Auth Server "server1")# key
"presharedkey"
(scalance)(Auth Server "server1")# exit
(scalance)(config)# wlan auth-server server2
(scalance)(Auth Server "server1")# ip
10.2.2.2
(scalance)(Auth Server "server1")# port 1812
(scalance)(Auth Server "server1")# acctport
1813
(scalance)(Auth Server "server1")# key
"presharedkey"
See Configuring an
External Server for Au-
thentication
6. Configure wired and wireless SSIDs
using the authentication servers and
access rules; enable authentication
survivability.
Configure wired ports to operate in Centralized, L2
mode and associate VLAN 20 to the wired port pro-
file.
(scalance)(config) # wired-port-profile
wired- port
(scalance)(wired-port-profile "wired-port")#
switchport-mode access
(scalance)(wired-port-profile "wired-port")#
allowed-vlan all
(scalance)(wired-port-profile "wired-port")#
native-vlan 20
(scalance)(wired-port-profile "wired-port")#
no shutdown
(scalance)(wired-port-profile "wired-port")#
access-rule-name wired-port
(scalance)(wired-port-profile "wired-port")#
type employee
(scalance)(wired-port-profile "wired-port")#
auth-server server1
(scalance)(wired-port-profile "wired-port")#
auth-server server2
(scalance)(wired-port-profile "wired-port")#
dot1x
(scalance)(wired-port-profile "wired-port")#
exit
(scalance)(config)# enet1-port-profile
wired-port
Configure a wireless SSID to operate in Centralized,
L2 mode and associate VLAN 20 to the WLAN SSID
profile.
(scalance)(config) # wlan ssid-profile wire-
less- ssid
(scalance)(SSID Profile "wireless-ssid")#
enable
(scalance)(SSID Profile "wireless-ssid")#
type employee
(scalance)(SSID Profile "wireless-ssid")#
essid wireless-ssid
(scalance)(SSID Profile "wireless-ssid")#
opmode wpa2-aes
(scalance)(SSID Profile "wireless-ssid")#
vlan 20
(scalance)(SSID Profile "wireless-ssid")#
auth- server server1
(scalance)(SSID Profile "wireless-ssid")#
auth- server server2
(scalance)(SSID Profile "wireless-ssid")#
auth- survivability
See Configuring a Wired
Profile and Wireless
Network Profiles
Содержание SCALANCE W1750D UI
Страница 18: ...About this guide SCALANCE W1750D UI 18 Configuration Manual 02 2018 C79000 G8976 C451 02 ...
Страница 28: ...About SCALANCE W 3 3 SCALANCE W CLI SCALANCE W1750D UI 28 Configuration Manual 02 2018 C79000 G8976 C451 02 ...
Страница 108: ...IPv6 Support 10 4 Debugging Commands SCALANCE W1750D UI 108 Configuration Manual 02 2018 C79000 G8976 C451 02 ...
Страница 326: ......
Страница 356: ......
Страница 374: ......
Страница 416: ......
Страница 440: ......
Страница 450: ...Intrusion Detection 27 4 Configuring IDS SCALANCE W1750D UI 450 Configuration Manual 02 2018 C79000 G8976 C451 02 ...
Страница 470: ......
Страница 480: ......
Страница 496: ......
Страница 518: ...Hotspot Profiles 33 3 Sample Configuration SCALANCE W1750D UI 518 Configuration Manual 02 2018 C79000 G8976 C451 02 ...
Страница 528: ......
Страница 552: ......
Страница 570: ...Appendix B 3 Glossary SCALANCE W1750D UI 570 Configuration Manual 02 2018 C79000 G8976 C451 02 ...