Basic Documentation LMU54... / LMU64...
CC1P7494en
HVAC Products
3 Functions
07.11.2002
If, with regard to the switching program and the feedback signal from the room, different
plant components are connected, the following table applies for the assignment to the
heating circuits and the demands for heat .
When a RU is used, a room thermostat or time switch cannot be connected to that input.
For this reason, the table does not include these combinations.
Heating circuits of the RU are interpreted as nonexisting if, via the
→
configuration of
the heating circuits, they have not been parameterized as controlling heating circuits, or
if the heating curve slope has been deactivated.
RT1 or
SU1
RT2 or
SU2
RU
RU1
RU2
Heat demand
HC1
Heat demand
HC2
Not present
Not present
–
Not present
Not present
–
–
Present
Not present
–
Not present
Not present
RT1 / SU1 1) 2)
–
Not present
Present
Not present
Not present
Not present
–
RT2 / SU2 1)
Present
Present
Not present
Not present
Not present
RT1 / SU1 1) 2)
RT2 / SU2 1)
Present
Not present
Present
Not present
Not present
RT1 / SU1 1) 2)
RT1 / SU1 1)
Not present
Not present
Present
Present
Not present
RU1
–
Present
Not present
Present
Present
Not present
RU1
RT1 / SU1 1)
Not present
Not present
Present
Not present
Present
–
RU2
Present
Not present
Present
Not present
Present
RT1 / SU1 1) 2)
RU2
Not present
Not present
Present
Present
Present
RU1
RU2
Present
Not present
Present
Present
Present
RU1
RU2
RT1
Room thermostat connected to RT input
SU1
Time switch connected to RT input
RT2
Room thermostat connected to OpenTherm input
SU2
Time switch connected to OpenTherm input and activated
(«KonfigRg1.Schaltuhr2Bw» = 0 and «KonfigRg1.Schaltuhr» = 1)
RU
RU connected to OT input
RU1
Heating circuit of the RU, which controls heating circuit 1 of the LMU...
RU2
Heating circuit of the RU, which controls heating circuit 2 of the LMU...
–
Present or not present
1)
Depending on parameter «KonfigRg1», time switch 1 / 2, following applies :
If this parameter = 1, time switch 1 / 2 is used
If this parameter = 0, room thermostat 1 / 2 is used
2)
If, with the AGU2.310, time switch operation is parameterized, the contact will
not
be evaluated and replaced by the switching program of the operating section
Combinations of RU and
room thermostat / time
switch
Legend