12/171
Siemens Building Technologies
Basic Documentation LMU54... / LMU64...
CC1P7494en
HVAC Products
1 Overview
07.11.2002
•
Integrated DHW systems with specific algorithms for storage tank, stratification
storage tank, instantaneous and aquabooster systems
•
Instantaneous DHW heating systems with optional comfort function
•
DHW heating with charging pump / diverting valve
•
Diverting valve control via stepper motor control, N.O. contact with continuous phase
or changeover contact
•
DHW control with sensor or thermostat
•
Control of DHW circulating pump with QAA73...-V1.4
•
Integrated weather-compensated pump heating circuit
•
PWM-controlled heating circuit pump with specific algorithms to ensure most effective
condensation, improved overall efficiency and enhanced room comfort (optional)
•
Additional weather-compensated heating circuit for single-user applications via
modular clip-in add-on module AGU2.500 (pump or mixing heating circuit) with
independent minimum / maximum limitation and heating curve.
Independent time switch program in connection with the QAA73...
•
Automatic summer / winter changeover
•
Automatic 24-hour heating limit (with no RU connected)
•
Quick setback (with no RU connected)
•
Compensation variants with room thermostat / time switch (single- or dual-channel
time switch)
•
Compensation variants with room controls via integrated interface based on
OpenTherm (QAA73... / QAA53...)
•
Integrated interface on OpenTherm basis
•
Communication capability via the
L
ocal
P
rocess
B
us (LPB) by means of clip-in
module
•
Consistent system architecture of RVA… controllers
•
Optional remote supervision
•
Connection via LPB clip-in module to
−
RVA46...
zone controllers
−
RVA47...
cascade controllers
−
RVA63...
boiler and heating circuit controllers
−
RVA65...
energy managers for solar, wood, etc.
−
RVA66...
boiler and heating circuit controllers
−
OCI6...
communication interface for remote supervision (in connection with
appropriate ACS… software)
1)
•
Modular and flexible concept of operating units AGU2.3...; optionally with housings for
flush panel mounting, degree of protection IPX4D (splash-proof) and LCD model with
clock function and backlit display
•
Chimney sweep function
•
Controller stop function for output adjustment
•
Error messages with lockout storage and fault history
•
Display and interrogation of all relevant process parameters via operating units,
QAA73... and PC tool
•
Counter for the number of startups and the number of operating hours
•
Maintenance functions with service message
1)
•
Automatic plant configuration (identification of RU, connected HMI, sensors, etc.)
1)
Planned; on request
DHW
Heating circuit
System application
Operation / service