![Siemens Brodersen MC55 Скачать руководство пользователя страница 86](http://html.mh-extra.com/html/siemens/brodersen-mc55/brodersen-mc55_command-manual_374181086.webp)
MC55_ATC_V04.00
Page 86 of 475
3/17/06
Confidential / Released
4.2
AT&C Set Data Carrier Detect (DCD) Line mode
The
AT&C
command determines how the state of the DCD line (circuit 109) reflects the MC55's internal activity.
Syntax
Parameter Description
[0]
DCD line shall always be on.
1
(&F)
DCD line shall be on only when data carrier signal is present.
2
DCD line shall be on when one or more Internet services defined on the related
serial channel are in state "Connecting" or "Up" as described below. For details
on the various service states refer to
AT^SISI
, parameter
<srvState>
or
AT^SISO
, parameter
<srvState>
.
• SOCKET, HTTP, SMTP, POP3: DCD shall be on when
<srvState>
="Connnecting" or "Up"
• FTP: DCD shall be on when data channel is connected, i.e.
<srvState>
="Up"
Exec Command
AT&C
[
<value>
]
Response(s)
OK
Reference(s)
PIN
ASC0 ASC1
MUX1
MUX2
MUX3 Charge
Last
V.250 , SIEMENS
!
%
!
%
%
%
!
!
!
<value>
(num)(&W)(&V)