![Siemens Brodersen MC55 Скачать руководство пользователя страница 326](http://html.mh-extra.com/html/siemens/brodersen-mc55/brodersen-mc55_command-manual_374181326.webp)
MC55_ATC_V04.00
Page 326 of 475
3/17/06
Confidential / Released
12.24
AT+FRS Receive Silence
<time>
=n causes the TA to report an OK result code to the TE after the specified period of silence was detected
on the line.
The command is aborted if any character is received by the TE. The modem discards the aborting character and
issues an OK result code. An ERROR response code results if this command is issued while the mode is on-
hook.
Syntax
Parameter Description
Number of 10 millisecond intervals
0...255
Note
• Used for Fax Class 1 only
Write Command
AT+FRS=
<time>
Response(s)
OK
If error is related to ME functionality:
ERROR
Reference(s)
PIN
ASC0 ASC1
MUX1
MUX2
MUX3 Charge
Last
TIA/EIA-578
!
%
!
%
!
!
!
!
!
<time>
(num)