Restart Lock acc. to Safety Concept K2
sinudyn-36
Hardware Description 0360520
83
13.2
Wiring Example
Combining a safe emergency stop command device, an OSSD safety switch device
or a light barrier with OSSD outputs and the safe switching off of the pulse patterns
allows creation of an error detection circuit, which achieves a safe stop (according to
stop function category 0+1), which meets the safety requirements according to SIL 3
(EN 13849-1). This circuit allows connecting several emergency stop devices in par-
allel, which are permanently monitored.
b
/
The external 24 V voltage supply must be protected against over-
voltages.
Warning
The safety device as well as the emergency stop device must be cer-
tificated as safety devices of SIL 3 to obtain safety level 4 according
to EN 13849-1.
Warning
In order to obtain the safety level SIL 3 according to EN 13849-1 the
circuit and the layout have been dimensioned according to IEC
60664-1:2008-01 pollution 2. Supporting material according to IEC
60249 covered by a non-aging protective coat of lacquer according
to IEC 60664-3 have been used. The conformity of standard have
been tested and approved by the TÜV-Nord CERT.
Содержание sinudyn-0360520 Series
Страница 7: ...Symbols 6 Symbols...
Страница 13: ...Safety Instructions and Application Advice 12 Safety Instructions Application Advice...
Страница 15: ...Unit Assembly Complying EMC 14 EMC...
Страница 53: ...Functional Description of the Connectors Interfaces 52 Hardware Description 0360520xx sinudyn 36...
Страница 59: ...Specification of the Digital Inputs and Outputs 58 Hardware Description 0360520xx sinudyn 36...
Страница 75: ...General Information Regarding the Wiring 74 Hardware Description 0360520xx...
Страница 93: ...Appendix Manufacturers 92 List of Manufacturers...