Functional Description of the Connectors/Interfaces
sinudyn-36
Hardware Description 0360520xx
45
8.2.9
X30 and X31 - Power Supply
X
two 6-pole Power CombiCon
Pin
Designation
X30
1
L1
Main supply. The intermediate circuit voltage depends on the input voltage. Ex-
ample: 3 x 400 V
AC
-10 %/+20 % for an intermediate circuit voltage of 560 V.
2
L2
3
L3
4
PE
earth conductor
5
LL1
Logic voltage supply. The logic voltage supply must always be connected (same
potential as main supply, see "Technical Data“,
).
6
LL2
X31
1
-UB
Intermediate circuit voltage -
2
-UB
3
+UB
Intermediate circuit v
4
+UB
5
REX
1
External ballast resistor*
6
RBRIDGE
1
must be bridged with REX if no external ballast resistor is existent
1
If an external ballast resistor is used, the wire strap between X31/5 and 6 must
be removed. The external ballast resistor is then connected bUB and
REX.
Warning
LL1
and
LL2
must always be connected. The angle pulses and error
messages are kept in case of an EMERGENCY STOP situation. If
the main voltage supply is turned off, make sure that all three mains
phases are also turned off! For this reason a main contactor with po-
sitively driven contacts must be used.
Содержание sinudyn-0360520 Series
Страница 7: ...Symbols 6 Symbols...
Страница 13: ...Safety Instructions and Application Advice 12 Safety Instructions Application Advice...
Страница 15: ...Unit Assembly Complying EMC 14 EMC...
Страница 53: ...Functional Description of the Connectors Interfaces 52 Hardware Description 0360520xx sinudyn 36...
Страница 59: ...Specification of the Digital Inputs and Outputs 58 Hardware Description 0360520xx sinudyn 36...
Страница 75: ...General Information Regarding the Wiring 74 Hardware Description 0360520xx...
Страница 93: ...Appendix Manufacturers 92 List of Manufacturers...