![SIEB & MEYER sinudyn-0360520 Series Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/sieb-and-meyer/sinudyn-0360520-series/sinudyn-0360520-series_hardware-description_1264951038.webp)
Functional Description of the Connectors/Interfaces
sinudyn-36
Hardware Description 0360520xx
37
/
A shielded cable should be used. Consider the documentation "Unit
Assembly Complying EMC and Supply System Types".
Warning
If no external current reference value is preset, the corresponding an-
alog inputs must be defined as follows: Analog-In+ to +5V, Analog-
In- to -5V. The internal current reference value can also be defined
via the software.
Control
+
-
4,7 k
6
20 k
6
20 k
6
4,7 k
6
3,3 nF
3,3 nF
100pF
100pF
Analog signal
Analog signal
+
-
+
-
Connector X2
Pin
Analog-In 2+
Analog-In 2-
2
1
+
-
20 k
6
20 k
6
4,7 k
6
3,3 nF
3,3 nF
100pF
100pF
Analog-In 1+
Analog-In 1-
3
7
8
6
Analog-Out 1
Analog-Out 2
33 pF
33 pF
1 k
6
Servo module
1 k
6
4,7 k
6
Содержание sinudyn-0360520 Series
Страница 7: ...Symbols 6 Symbols...
Страница 13: ...Safety Instructions and Application Advice 12 Safety Instructions Application Advice...
Страница 15: ...Unit Assembly Complying EMC 14 EMC...
Страница 53: ...Functional Description of the Connectors Interfaces 52 Hardware Description 0360520xx sinudyn 36...
Страница 59: ...Specification of the Digital Inputs and Outputs 58 Hardware Description 0360520xx sinudyn 36...
Страница 75: ...General Information Regarding the Wiring 74 Hardware Description 0360520xx...
Страница 93: ...Appendix Manufacturers 92 List of Manufacturers...