![SIEB & MEYER sinudyn-0360520 Series Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/sieb-and-meyer/sinudyn-0360520-series/sinudyn-0360520-series_hardware-description_1264951032.webp)
Functional Description of the Connectors/Interfaces
sinudyn-36
Hardware Description 0360520xx
31
A shielded line, 3 times twisted-pair must be used. Twist mode: sine/sine, cosine/co-
sine, rotor/rotor; designation of the line, e.g. LIYCY 3 × 2 × 0.14. If the thermal motor
protection is evaluated, a 4 times twisted-pair, shielded line must be used.
2
If no thermal motor protection is connected, pin 15 and pin 7 must be connected to each other,
see connection diagram "Thermal motor protection",
Resolver
S1
Sine
S3
Cosine
S4
Rotor
R3
S2
R1
+
-
Connector X1
Pin
+
-
+
-
+
-
S1
S3
S4
S2
R3
R1
2
9
4
11
6
13
22nF
1nF
22n
1nF
1nF
6.8 k
6
22nF
3.9 k
6
22nF
33nF
33
6
33
6
6.8 k
6
33nF
10 k
6
20 k
6
470pF
6.8 k
6
6.8 k
6
3.9 k
6
6.8 k
6
6.8 k
6
3.9 k
6
3.9 k
6
Servo Module
2x1mH/0.5 A
2x1mH/0.5 A
Содержание sinudyn-0360520 Series
Страница 7: ...Symbols 6 Symbols...
Страница 13: ...Safety Instructions and Application Advice 12 Safety Instructions Application Advice...
Страница 15: ...Unit Assembly Complying EMC 14 EMC...
Страница 53: ...Functional Description of the Connectors Interfaces 52 Hardware Description 0360520xx sinudyn 36...
Страница 59: ...Specification of the Digital Inputs and Outputs 58 Hardware Description 0360520xx sinudyn 36...
Страница 75: ...General Information Regarding the Wiring 74 Hardware Description 0360520xx...
Страница 93: ...Appendix Manufacturers 92 List of Manufacturers...