Functional Description of the Connectors/Interfaces
sinudyn-36
Hardware Description 0360520xx
35
8.2.1.5
Wiring Diagram for the Termal Motor Protection
INPUT/OUTPUT: The thermal motor protection is evaluated via these connectors.
The servo amplifier supports the evaluation by means of the temperature monitoring
intagrated in the motor. The NTC/PTC behavior of the monitoring is defined in the
software (motor parameters). The controller is deactivated when the critical motor
temperature is reached.
/
If no thermal motor protection is connected, pin 7 and pin 15 must be
bridged.
10k
6
11,5 k
6
0,1
F
+24 V
Servo module
Motor
NTC
PTC
Thermal contact
K
K
Pin 7
Pin 15
K