Name
Use
Data type
Definition
Values
Safety implica‐
tion
BOOL
Control input 1 (A1)
State of the static con‐
trol input for monitoring
case switching.
0 = logic status
of the control
input is 0
Safety-relevant
parameter
1 = logic state of
the control input
is 1
control input 2 (A2)
…
control input 16 (H2)
BOOL
Control input 2 (A2) …
16 (H2)
State of the static con‐
trol input for monitoring
case switching.
0 = logic status
of the control
input is 0
Safety-relevant
parameter
1 = logic state of
the control input
is 1
ControlInputsValid
BOOL
State of the valid static
control inputs
0 = inputs invalid Safety-relevant
parameter
1 = inputs valid
CurrentMonitoringCaseNoTa‐
ble1
Diagnostics
USINT
Current monitoring
case (Monitoring case
table 1)
Signals the current
(active) monitoring case
of monitoring case
table 1.
0 = no monitor‐
ing case is active
Parameter with‐
out safety impli‐
cation
1 … 254 = num‐
ber of the current
(active) monitor‐
ing case
CurrentMonitoringCaseNoTa‐
ble2
Diagnostics
USINT
Current monitoring
case (Monitoring case
table 2)
Signals the current
(active) monitoring case
of monitoring case
table 2.
0 = no monitor‐
ing case is active
Parameter with‐
out safety impli‐
cation
1 … 254 = num‐
ber of the current
(active) monitor‐
ing case
CurrentMonitoringCaseNoTa‐
ble3
Diagnostics
USINT
Current monitoring
case (Monitoring case
table 3)
Signals the current
(active) monitoring case
of monitoring case
table 3.
0 = no monitor‐
ing case is active
Parameter with‐
out safety impli‐
cation
1 … 254 = num‐
ber of the current
(active) monitor‐
ing case
CurrentMonitoringCaseNoTa‐
ble4
Diagnostics
USINT
Current monitoring
case (Monitoring case
table 4)
Signals the current
(active) monitoring case
of monitoring case
table 4.
0 = no monitor‐
ing case is active
Parameter with‐
out safety impli‐
cation
1 … 254 = num‐
ber of the current
(active) monitor‐
ing case
DeviceError
Diagnostics
BOOL
Device error
Signals whether an
application error (seri‐
ous error) is present,
causing the safety func‐
tion to be paused. To
resolve this, rectify the
cause of the error and
then restart the device.
0 = no device
error
Parameter with‐
out safety impli‐
cation
1 = device error
TECHNICAL DATA
13
8025424/1ELL/2022-01-21 | SICK
O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O
197
Subject to change without notice