Menu
The menu provides access to the following areas:
•
Device info
•
Diagnostics
•
Device restart
•
Settings
Approach
b
Press the OK pushbutton
4
twice in succession to call up the menu.
b
Use the arrow buttons
1
,
2
to change to the desired menu item.
b
Confirm the desired menu item using the OK pushbutton
4
.
b
Use the same pushbuttons to navigate through the submenus.
b
Press the Back pushbutton
3
to return to the higher-level menu item.
b
Press the Back pushbutton
3
multiple times to return to the status display.
b
Do not press any pushbutton for some time so that the display returns to the
status display.
Device info
You will find information about the following subjects in the area:
•
Hardware
: For example type code, part numbers, serial numbers, firmware versions,
functional scope of device
•
Configuration
: For example device name, application name, checksum, date of last
configuration, functional scope of configuration
•
Service interfaces
: Information on whether access to individual interfaces and serv‐
ices is activated or deactivated
•
Fieldbus
: For example MAC address, IP address, subnet
•
Data output
: For example status, destination IP address
The
Functionality of the device
and
Functionality of the configuration
show whether a configu‐
ration is compatible with the firmware version of a device. This can be important when
exchanging a device, for example.
Configuration and firmware version of a device are compatible if the following condi‐
tions are met:
•
The 1st place of both numbers must be identical
•
The 2nd place for the device must be at least as large as that for the configuration
•
The 3rd place does not have an effect on the compatibility
Diagnostics
Check whether the safety laser scanner is being dazzled by an external light source in
the scan plane, e.g., sun, halogen light, infrared light source.
•
Intrusions
: Position and time of the last 10 objects in a protective field that have led
to a safety output switching to the OFF state.
•
Messages
: Error code and error type of the last 10 error messages.
•
Service
: Currently measured contamination of the optics cover, operating hours,
number of power-up processes.
Device restart
You have the following options in the
Device restart
area:
•
Restart the safety laser scanner.
Settings
You have the following options in the
Settings
area:
•
Set the display brightness and contrast.
TROUBLESHOOTING
11
8025424/1ELL/2022-01-21 | SICK
O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O
167