Table 2: Field types and their function
1)
Safe switch off
(according to ISO
13849-1)
Yes (PL d)
Yes (PL d)
Yes (PL d)
Yes (PL d)
No
Max. scanning
range of the
safety laser scan‐
ner
Variant-
dependent:
4.0 m
5.5 m
9.0 m
Variant-
dependent:
4.0 m
5.5 m
9.0 m
Variant-
dependent:
4.0 m
5.5 m
9.0 m
19.0 m
Variant-
dependent:
40 m
64 m
Purpose
Detection
and protec‐
tion of people
Tamper pro‐
tection
e.g. door
monitoring
Detection of
an oncoming
industrial
truck in a nar‐
row aisle. Use
is only permit‐
ted in accord‐
ance with the
description in
this docu‐
ment,
"Collision pro‐
tection in nar‐
row aisles",
page 58
.
Functional
use (no
safety-rele‐
vant use)
1)
Available only for devices with the Pro performance package and a maximum protective field range of
9 m.
The protective field protects the hazardous area of a machine or vehicle. As soon as the
electro-sensitive protective device detects an object in the protective field, it switches
the associated safety outputs to the OFF state. This signal can be passed to controllers
resulting in the dangerous state coming to an end, e.g. to stop the machine or the
vehicle.
Figure 5: Protective field, shown in red in this document
PRODUCT DESCRIPTION
3
8025424/1ELL/2022-01-21 | SICK
O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O
17
Subject to change without notice