microScan3 Pro I/O
Incremental encoders that can be evaluated
Type Dual-channel, 90° phase separation
Enclosure rating IP54 or better
Outputs required on the
incremental encoders
Push-pull
Number of pulses per path ≥ 100 pulses per cm
Length of cable (shielded) ≤ 20 m
1)
The power supply unit must be able to jumper a brief power failure of 20 ms as specified in
IEC 60204-1. Suitable power supply units are available as accessories from SICK.
2)
The voltage level must not fall below the specified minimum voltage.
3)
Total output current of all outputs ≤ 2.8 A.
4)
In the event of a fault (interruption of the 0 V cable), the specified leak current at most flows in the OSSD
cable. The downstream control element must detect this state as the OFF state.
5)
Time from the occurrence of the event until the output is switched on.
6)
Time from the occurrence of the event until the output is switched off.
7)
Per connection.
Mechanical data
Table 35: Mechanical data
microScan3 Pro I/O
Dimensions (W × H × D)
112 mm × 163 mm × 111.1 mm
Weight (including system
plug)
1.6 kg
Housing material
Aluminum
Housing color
RAL 9005 (black) and RAL 1021 (colza yellow)
Optics cover material
Polycarbonate
Optics cover surface
Outside with scratch-resistant coating
Ambient data
Table 36: Ambient data
microScan3 Pro I/O
Enclosure rating
1)
IP65 (IEC 60529)
Ambient light immunity
≤ 40 klx
2)
Ambient operating tempera‐
ture
–10 °C … 50 °C
Storage temperature
–25 °C … 70 °C
Air humidity
≤ 95%, non-condensing
3)
Height above sea level during
operation
≤ 2,300 m
Vibration resistance
4)
Standards
•
IEC 60068-2-6
•
IEC 60068-2-64
•
IEC 60721-3-5
•
IEC TR 60721-4-3
•
IEC 61496-1
•
IEC 61496-3
Class
•
5M1 (IEC 60721-3-5)
•
3M4 (IEC TR 60721-4-3)
13
TECHNICAL DATA
184
O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O
8025424/1ELL/2022-01-21 | SICK
Subject to change without notice