Name
Use
Data type
Definition
Values
Safety implica‐
tion
ManipulationStatus
Diagnostics
BOOL
Manipulation
Signals if manipulation
has been detected
and the safety outputs
are therefore in the
OFF state, for example
because the device has
not detected an object
over a long period of
time.
0 = no manipula‐
tion detected
Parameter with
implication for
the safety func‐
tion
1 = manipulation
detected
NonsafeCutOffPath01
Additional func‐
tion
BOOL
Cut-off path 01 (Not
safety-related)
The signal is ON if
the currently monitored
field in the cut-off path
is free.
0 = OFF state,
field interrupted
Parameter with‐
out safety impli‐
cation
1 = ON state,
field free
NonsafeCutOffPath02
…
NonsafeCutOffPath08
Additional func‐
tion
BOOL
Cut-off path 02 … 08
(Not safety-related)
The signal is ON if
the currently monitored
field in the cut-off path
is free.
1)
0 = OFF state,
field interrupted
Parameter with‐
out safety impli‐
cation
1 = ON state,
field free
ReferenceContourStatus
Diagnostics
BOOL
Reference contour
monitoring
The safety laser scan‐
ner does not detect a
contour in the set toler‐
ance band. All safety
outputs in the OFF
state.
0 = contour in
the set tolerance
band or refer‐
ence contour
monitoring not
active
Parameter with
implication for
the safety func‐
tion
1 = contour not
in set tolerance
band
ResetRequiredCutOffPath01
Diagnostics
BOOL
Reset required, Cut-off
path 01
Signals whether the
device is waiting for a
reset signal to switch
safety-related cut-off
path 01 to the ON
state.
0 = reset not
required
Parameter with
implication for
the safety func‐
tion
1= reset required
ResetRequiredCutOffPath02
…
ResetRequiredCutOffPath08
Diagnostics
BOOL
Reset required, Cut-off
path 02 … 08
Signals whether the
device is waiting for a
reset signal to switch
the respective safety-
related cut-off path to
the ON state.
1)
0 = reset not
required
Parameter with
implication for
the safety func‐
tion
1= reset required
RunModeactive
Diagnostics
BOOL
Signals the operational
status of the device.
Parameter with‐
out safety impli‐
cation
1 = safety func‐
tion is executed.
13
TECHNICAL DATA
198
O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O
8025424/1ELL/2022-01-21 | SICK
Subject to change without notice