Speed
•
Range
: The monitoring case is activated if the speed is within the specified range.
You can use static control inputs as additional input conditions.
•
Limit
: The monitoring case is activated via the static control inputs. The safety laser
scanner monitors the speed. If the speed is outside the specified range, the safety
laser scanner switches the safety outputs to the OFF state.
In this mode, the safety laser scanner ignores different speeds of the two incre‐
mental encoders for 60 seconds, even if the difference is greater than the config‐
ured tolerance.
Complementary information
The
Generate input conditions
function allows you to automatically assign input conditions
to monitoring cases.
7.14.5
Cut-off paths
You can create cut-off paths and define the outputs switched by the cut-off paths.
(Example: the protective fields switch the OSSD pair, the warning fields switch a univer‐
sal output.)
You need a cut-off path for every field in a field set. If the field sets have different sizes,
use the field set with the most fields as a guide.
Creating cut-off path and entering a name
1.
Create a cut-off path for every field in the largest field set.
2.
Enter a descriptive name for each cut-off path.
Assigning an OSSD pair
b
Place a check in the box for the OSSD pair.
✓
The OSSD pair is assigned to the cut-off path.
Assigning the number of the cut-off path in the assembly
b
Select the desired number.
✓
The number is assigned to the cut-off path.
Assigning unsafe outputs
b
Place a check in the box for the universal output(s).
✓
The universal output is assigned to the cut-off path.
Restart behavior
You define the restart behavior for all network outputs in the
Inputs and outputs
window.
If needed, define a deviating restart behavior for one or several network outputs.
7.14.6
Assigning field sets
Assigning a field set to a monitoring case
The field sets that have been created are listed in the
Field sets
area.
1.
Create cut-off paths,
.
2.
Drag the field set onto the monitoring case.
✓
The fields in a field set are arranged as they were drawn in the field editor (for
example protective field, warning field, warning field).
7
CONFIGURATION
138
O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O
8025424/1ELL/2022-01-21 | SICK
Subject to change without notice