A static control input consists of 2 channels. To switch correctly, one channel must
be switched inversely to the other.
•
1-of-n
In the 1-of-n evaluation, use the channels of the control inputs individually. At any
time, exactly one channel must have logic value 1.
•
Case number
For certain assemblies, the monitoring cases are activated by their number.
Speed
You specify which source is used for the speed. If you use 2 non-safe speed sources,
also specify the tolerated deviation between the 2 signals.
Other functions
You specify which source is used to restart the device, put it into sleep mode, or pause
the event history.
Behavior after connection gets lost
You can configure the way in which the device behaves when secure communication
is reestablished in the network after an interruption:
•
Manual start through “Restart safety function” action
After canceling secure communication, the safety function is stopped and the
device reports an application error. Once the connection is established again, you
must send the command
Restart safety function
to the device via the assembly or via
Safety Designer.
•
Automatic start after connection
After aborting the safe communication, the safety laser scanner signals to
Wait for
inputs
. As soon as the connection has been reestablished, the device automatically
switches to the current monitoring case. No additional command is required.
Local outputs
Safety Designer shows which local outputs are configured.
Remote switching
A host in a host-guest group can use the monitoring results of the guest devices to
switch the local outputs. The local outputs then map both the local monitoring results
and the monitoring results of the guest devices.
Under
Remote switching
, you can set whether the monitoring results of the guest devices
are used to switch the local outputs. In addition, you set which local output is switched
for each assembly and each cut-off path of the guest devices.
Restart behavior
You define whether the internal restart interlock of the network outputs is used.
If necessary, specify which assembly is used for resetting.
Available network outputs
Safety Designer displays which network outputs are available.
7
CONFIGURATION
130
O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O
8025424/1ELL/2022-01-21 | SICK
Subject to change without notice